| INSTALLATION |
| ||
|
|
|
|
|
POWER INPUT CONNECTION FOR 50/60 HZ MACHINES
1. Connect terminal marked |
|
|
|
|
| to earth ground |
per National Electric Code. |
|
|
|
2.Connect the supply lines to the line switch. Torque to 3.0 Nm.
3.Install in accordance with all local and national electric codes.
The Invertec
Strip away outer jacket of cord, trim fillers and insert conductors through cord connector. The jacketed por- tion of the cord must go through the cord connector. Tighten both connector screws.
INPUT FUSE AND SUPPLY WIRE
Refer to the Technical Specifications page at the beginning of this chapter for the proper fuse sizes and supply cable sizes.
•Fuse the input circuit with recommended super lag fuses or delay type circuit breakers.
•Install the proper fuse in the fuse holder in the main disconnect panel.
INPUT VOLTAGE RECONNECT PROCEDURE
When received directly from the factory, units are con- nected for the highest input voltage, 440 VAC for 50/60 Hz machines and 460 VAC for 60 Hz machines. If 440 or 460 VAC is the desired input, then the machine may be connected to the power system with- out any setup required inside the reconnect door. However, verify the connection with the following pro- cedure. For other voltages refer to the instructions located on the Reconnect Panel Access Door or fol- low the instructions below.
CAUTION
Failure to follow these instructions can cause immedi- ate failure of components within the welder.
1.Open the access door on the right side of the machine.
2.For
For
3.Move the “A” lead to the appropriate terminal. Refer to figure A.1 below.
RECONNECT PROCEDURE | . Disconnect input power before | |
1. BE SURE POWER SWITCH IS OFF. | ||
inspecting or servicing machine. |
2. CONNECT LEAD 'A' TO DESIRED | . Do not operate with wraparound | |||
INPUT VOLTAGE RANGE. |
|
| removed. | |
| . Do not touch electrically live parts. | |||
| . | Only qualified persons should install, | ||
| 'A' | |||
use or service this equipment. | ||||
| ||||
| IF MACHINE CEASES TO OPERATE (NO METER, NO FAN) | |||
|
| |||
| AND THERE IS NO OTHER KNOWN FAILURE: CHECK FUSE; | |||
|
| REPLACE WITH SPECIFIED FUSE. |
3. POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.
THE LINCOLN ELECTRIC CO . CLEVELAND, OHIO U . S . A .
A
S21230