PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

Major physical or electrical damage

 

 

is observed when cover wrap-around

 

 

is removed.

 

 

 

 

 

The machine is dead - no output -

1.

The input power switch must be

no fan.

 

in the ON position.

 

2.

Make sure the input voltage is

 

 

correct for the machine.

 

3.

If the machine is set for single-

 

 

phase operation, inspect to

 

 

assure that the WHITE and

 

 

BLACK leads are connected

 

 

properly and the RED lead is not

 

 

connected and is insulated.

 

4.

Check that the input voltage set-

 

 

up switch and jumper “A” (the

 

 

reconnect auxiliary jumper) are in

 

 

the proper position for the input

 

 

voltage being applied. Refer to

 

 

Input Voltage Reconnect

 

 

Procedure in the Installation

 

 

Chapter.

 

5.

Check continuity of the 0.6-amp

 

 

slow blow fuse located on the

 

 

reconnect panel.

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.