| INSTALLATION |
| ||
|
|
|
|
|
Read this entire installation section before you start installation.
SAFETY PRECAUTIONS
WARNING
ELECTRIC SHOCK can kill.
•Have an electrician install and ser- vice this equipment.
•Turn the input power off at the fuse box before working on equipment.
•Do not touch electrically hot parts.
•Be sure to discharge capacitors with the procedure outlined in the Maintenance Section of this manual before working in that area of the equipment.
SELECT SUITABLE LOCATION
The Invertec
•The machine must be located where there is free cir- culation of clean air such that air movement in the back and out the front will not be restricted.
•Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shutdown.
•Keep machine dry. Shelter from rain and snow. Do not place on wet ground or in puddles.
STACKING
TILTING
Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine may topple over if this procedure is not followed.
HIGH FREQUENCY PRECAUTIONS
If possible locate the
INPUT CONNECTIONS
The Invertec
GROUND CONNECTION
Ground per National Electrical Code for 60Hz machines connect the green lead to earth ground. For 50/60Hz machines connect the ground terminal
marked located in the machine on the lower right side the base of the welder to earth ground.
INPUT SUPPLY CONNECTIONS
Be sure the voltage phase and frequency of the input power is as specified on the rating plate, located on the rear of the machine.
Supply line entry provision is in the case rear panel.
POWER INPUT CONNECTION FOR 60HZ MACHINES
A 10 ft. power cord is provided and wired into the machine. Follow the power cord connection instruc- tions. Incorrect connection may result in equipment damage.
Single Phase Input: Connect green lead to ground per U.S. National Electrical Code. Connect black and white leads to power. Wrap red lead with tape to pro- vide 600V insulation.
Three Phase Input: Connect green lead to ground per U.S. National Electrical Code. Connect black, red and white leads to power.