Manual background

 

E-5

 

 

 

TROUBLESHOOTING

 

E-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

TROUBLESHOOTING GUIDE

 

 

 

 

 

Observe Safety Guidelines

 

 

 

 

 

 

 

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine often “noodle welds” (out-

Secondary current limit has been

 

 

 

 

 

 

put is limited to approximately 100

 

 

exceeded, and the machine has

 

 

 

 

 

 

 

amps) when running a particular

 

 

phased back to protect itself.

 

 

 

 

 

 

 

procedure

 

 

Adjust procedure or reduce load to

 

 

 

 

 

 

 

 

 

 

 

lower current draw from the

 

 

 

 

 

 

 

 

 

 

 

machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine won’t produce full output.

 

 

1. Input voltage may be too low,

 

 

 

 

 

 

 

 

 

 

 

 

limiting output capability of the

 

 

 

 

 

 

 

 

 

 

 

 

power source. Make certain

 

 

 

 

 

 

 

 

 

 

 

 

that the input voltage is prop-

 

 

 

 

 

 

 

 

 

 

 

 

er, according to the Rating

 

 

 

 

 

 

 

 

 

 

 

 

Plate located on the rear of

 

 

 

 

 

 

 

 

 

 

 

 

the machine.

 

 

 

 

 

 

 

 

 

 

 

2.

Input may be “single phased”.

 

 

 

 

 

 

 

 

 

 

 

 

Make certain the input voltage

 

 

 

 

 

 

 

 

 

 

 

 

is proper on all three input

 

 

 

 

 

 

 

 

 

 

 

 

lines.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For no apparent reason, the weld-

 

 

1.

Check for proper Wire Feed

 

 

If all recommended possible areas

 

 

 

 

ing characteristics have changed.

 

 

 

Speed setting. In CV MIG

 

 

 

 

 

 

 

 

 

 

 

of misadjustments have been

 

 

 

 

 

 

 

 

 

and FCAW modes, check for

 

 

 

 

 

 

 

 

 

 

 

 

 

checked and the problem persists,

 

 

 

 

 

 

 

 

 

proper Voltage setting. In the

 

 

 

 

 

 

 

 

 

 

 

 

 

contact your local Lincoln

 

 

 

 

 

 

 

 

 

MIG/MAG pulse modes,

 

 

 

 

 

 

 

 

 

 

 

check the Trim setting. These

 

 

Authorized Field Service Facility.

 

 

 

 

 

 

 

 

 

controls are on the wire feed-

 

 

 

 

 

 

 

 

 

 

 

 

er.

 

 

 

 

 

 

 

 

 

 

 

2.

Check for proper shielding

 

 

 

 

 

 

 

 

 

 

 

 

gas mix and flow.

 

 

 

 

 

 

 

 

 

 

 

3.

Check for loose or faulty weld

 

 

 

 

 

 

 

 

 

 

 

 

cables and cable connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary receptacle is “dead” — no

 

 

1. Circuit breaker CB2 (on case

 

 

 

 

 

 

 

auxiliary voltage .

 

 

 

front) may have opened.

 

 

 

 

 

 

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

 

 

 

 

 

2.

Circuit breaker CB4 (in recon-

 

 

 

 

 

 

 

 

 

 

 

 

nect area) may have opened.

 

 

 

 

 

 

 

 

 

 

 

 

Reset.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electric Field Service Facility for technical assistance.

POWER WAVE 455

Page 25
Image 25
Lincoln Electric IM583-A Troubleshooting Guide, Problems, Possible Areas Of, Recommended, Symptoms, Misadjustments