Lincoln Electric IM583-A Installation, Technical Specifications - Power Wave, Physical Dimensions

Models: IM583-A

1 32
Download 32 pages 30.89 Kb
Page 8
Image 8
INSTALLATION

A-1

 

 

 

 

 

 

 

INSTALLATION

 

 

 

 

A-1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 455

 

 

 

 

 

 

INPUT AT RATED OUTPUT - THREE PHASE ONLY

 

 

INPUT VOLTS

 

OUTPUT

 

 

INPUT

 

 

 

 

 

OUTPUT

 

INPUT

 

 

 

 

CONDITIONS

 

CURRENT

 

 

CONDITIONS

 

CURRENT

208V - 60HZ.

 

450A@38V. 100%

 

 

70

 

 

 

 

 

570A@43V. 60%

 

87

230V - 60HZ.

 

450A@38V. 100%

 

 

65

 

 

 

 

 

570A@43V. 60%

 

82

400V - 60HZ.

 

450A@38V. 100%

 

 

39

 

 

 

 

 

570A@43V. 60%

 

50

460V - 60HZ.

 

450A@38V. 100%

 

 

35

 

 

 

 

 

570A@43V. 60%

 

48

575V - 60HZ.

 

450A@38V. 100%

 

 

29

 

 

 

 

 

570A@43V. 60%

 

38

200V - 50HZ.

 

400A@36V. 100%

 

 

72

 

 

 

 

 

500A@40V. 60%

 

79

220V - 50HZ.

 

400A@36V. 100%

 

 

67

 

 

 

 

 

500A@40V. 60%

 

74

400V - 50HZ.

 

400A@36V. 100%

 

 

40

 

 

 

 

 

500A@40V. 60%

 

45

440V - 50HZ.

 

400A@36V. 100%

 

 

36

 

 

 

 

 

500A@40V. 60%

 

41

550V - 50HZ.

 

400A@36V. 100%

 

 

29

 

 

 

 

 

500A@40V. 60%

 

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

OPEN

 

CURRENT

 

PULSE

 

PULSE

 

PULSE AND

 

 

AUXILIARY
CIRCUIT

 

 

RANGE

 

FREQUENCY

 

VOLTAGE

 

BACKGROUND

 

 

POWER

VOLTAGE

 

 

 

 

 

 

 

 

RANGE

 

TIME RANGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

75 VDC

 

5 - 570

 

0.15 - 1000 Hz

 

5 - 55 VDC

 

100 MICRO SEC. -

 

 

40 VDC AT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.3 SEC.

 

 

10 AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 VAC AT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROCESS CURRENT RANGES (DC)

 

 

 

 

 

 

 

CURRENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MIG/MAG

 

 

 

 

 

 

 

 

 

50-570 Amps

 

 

 

 

 

 

FCAW

 

 

 

 

 

 

 

 

 

 

40-570 Amps

 

 

 

 

 

 

SMAW

 

 

 

 

 

 

 

 

 

 

30-570 Amps

 

 

 

 

 

 

Pulse

 

 

 

 

 

 

 

 

 

 

5-750 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

INPUT

 

OUTPUT AMPS/
INPUT AMPERE

 

TYPE 75°C

TYPE 75°C

 

TYPE 75°C

VOLTAGE /

 

DUTY

 

RATING ON

 

COPPER WIRE
GROUND WIRE

 

(SUPER LAG)

FREQUENCY

 

CYCLE

 

NAMEPLATE

 

IN CONDUIT

IN CONDUIT

 

OR BREAKER

 

 

 

 

 

 

 

 

 

 

 

AWG[IEC] SIZES

AWG[IEC] SIZES

 

SIZE (AMPS)

 

 

 

 

 

 

 

 

 

 

 

 

 

(MM2)

 

(MM2)

 

 

208/60

 

 

450/100%

 

70

 

 

4 (25)

 

8 (10)

 

 

80 AMP

230/60

 

 

450/100%

 

65

 

 

4 (25)

 

8 (10)

 

 

70 AMP

400/60

 

 

450/100%

 

39

 

 

8 (10)

 

10 (6)

 

 

50 AMP

460/60

 

 

450/100%

 

35

 

 

8 (10)

 

10 (6)

 

 

40 AMP

575/60

 

 

450/100%

 

29

 

 

8 (10)

 

10 (6)

 

 

40 AMP

200/50

 

 

400/100%

 

72

 

 

4 (25)

 

8 (10)

 

 

80 AMP

220/50

 

 

400/100%

 

67

 

 

4 (25)

 

8 (10)

 

 

80 AMP

400/50

 

 

400/100%

 

35

 

 

8 (10)

 

10 (6)

 

 

50 AMP

440/50

 

 

400/100%

 

31

 

 

8 (10)

 

10 (6)

 

 

40 AMP

550/50

 

 

400/100%

 

29

 

 

8 (10)

 

10 (6)

 

 

40 AMP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

HEIGHT
WIDTH
DEPTH
WEIGHT

26.10 in

19.86 in

32.88 in

250 lbs.

663 mm

505 mm

835 mm

114 kg.

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

0°C to 40°C

STORAGE TEMPERATURE RANGE

-50°C to 85°C

POWER WAVE 455
Page 8
Image 8
Lincoln Electric IM583-A Installation, Technical Specifications - Power Wave, Recommended Input Wire And Fuse Sizes, Open