Lincoln Electric IM601-A manual Auxiliary Power Controls

Models: IM601-A

1 58
Download 58 pages 39.78 Kb
Page 22
Image 22

B-5

OPERATION

B-5

 

 

 

WELDER CONTROLS (Items 9 through 14 )

9. OUTPUT

SELECTOR SWITCH & OUTPUT

CONTROL

 

These two controls allow you to select between various welding output slopes and adjust the desired welding output. Refer to Table B.1 for a description of how these two controls work.

Table B.1 Output Range Switch and Output Control Functions

 

Selector

Control2

 

Switch1

 

Sloped Output for

5 Range

 

Pipe Welding.

Settings

 

 

60, 90, 150,

 

 

230, 300 (Max.

Provides a fine

 

current on each

adjustment of

 

setting)

welding current

Constant Current

 

from

1 Range setting

Min (1) to Max

Output for

30-375 Amps

(10) within each

Fabrication and

 

range

General Purpose

 

 

 

Welding (This set-

 

 

ting also used for

 

 

TIG)

 

 

Constant Voltage

1 Range setting

Provides Fine

Output for MIG

12 to 40 Volts

Voltage

Wire or CORED

 

Adjustment

WIRE Welding

 

 

1If the SELECTOR switch is positioned between settings the previ- ous setting is maintained until the switch is properly positioned on a setting.

2CONTROL also controls O.C.V. while in the 5 sloped output ranges.

10. DIGITAL OUTPUT METERS

The digital output meters are located in the center of the control panel between the two large control knobs. The meters allow the output current level to be set prior to welding in stick mode, and voltage level to be set prior to welding in the wire modes. During the welding process the meters display the actual output current and voltage, within +1%, -10% accuracy.

11. WELDING TERMINALS SWITCH

The toggle switch on the control panel labeled “Welding Terminals Always On” and “Welding Terminals Remotely Controlled”: is used to control the operation of the “solid state contactor” which allows for the selection of “Hot” or “Cold” welding terminals.

With the switch in the “Welding Terminals Always On” position the contactor is closed and the welding termi- nals are always “Hot”.

With the switch in the “Welding Terminals Remotely Controlled” position the contactor operation is con- trolled by an Amptrol, Arc Start Switch or some other type of triggering device through the use of a control cable connected to the 14-pin MS connector.

When the triggering device is pressed the contactor is closed and the welding terminals are “Hot”.

When the triggering device is released the contactor is opened and the welding terminals are “Cold”.

12. LOCAL /REMOTE SWITCH

The toggle switch on the control panel labeled “Local/Remote” gives the operator the option of con- trolling the output at the welder control panel or at a remote station.

For remote control the toggle switch is set in the “Remote” position.

For control at the welder control panel, the toggle switch is set in the “Local” position.

13. 6 - PIN CONNECTOR

The 6-pin connector located on the control panel allows for connection of interfacing equipment.

14. WELD OUTPUT TERMINALS + AND -

These 1/2 - 13 studs with flange nuts provide welding connection points for the electrode and work cables. For positive polarity welding the electrode cable con- nects to the “+” terminal and the work cable connects to this “-” terminal. For negative polarity welding the work cable connects to the “+” terminal and the elec- trode cable connects to this “-” terminal.

AUXILIARY POWER CONTROLS

(Items 15 - 19 )

15. 120/240VAC RECEPTACLE

This is a 120/240VAC (14-50R) receptacle that pro- vides 240VAC or can be split for 120VAC single phase auxiliary power. This receptacle has a 50 amp rating. Refer to the AUXILIARY POWER RECEPTACLES sec- tion in the installation chapter for further information about this receptacle. Also refer to the AUXILIARY POWER OPERATION section later in this chapter.

16. 50 AMP CIRCUIT BREAKERS These circuit breakers provide separate overload cur- rent protection for each 120V circuit at the 240V recep- tacle.

COMMANDER 300

Page 22
Image 22