Lincoln Electric IM620-B manual Dia. Hole, Drive Roll & Guide Tube Wire Sizes Used Kit No

Models: IM620-B

1 40
Download 40 pages 40.99 Kb
Page 26
Image 26

C-6

ACCESSORIES

C-6

 

 

 

 

The following Figures C.1 and C.2 should serve as a guide to determine if a particular gun or switch can be connected to the LN-25.

GUN CABLE CONNECTOR REQUIREMENTS

TO PERMIT PROPER CONNECTION TO

LINCOLN LN-25 WIRE FEEDER.

LN-25 Cable Connector for .023 through .052 Wire (For all other dimensions, see above)

FIGURE C.1

NOTE: Connector part with .749/.747 diameter should be made from brass if it is to be part of the welding current carrying circuit.

 

“A Dia. Hole”

 

To be Concentric to .749/.747

Wire Size

Dia. Within .008 F.I.M.

.068 thru 564

.125 (18 Drill)

 

 

 

116 (.062)

.078 (564

Drill)

 

 

 

.045 & .052

.062 (116

Drill)

 

 

.023 thru .035

.055 (#54 Drill)

 

 

 

Drive Roll & Guide Tube

Wire Sizes Used

Kit No.

 

 

 

T-13355-332

564, .072 & .068

T-13355-116(1)

116, .062

T-13355-.052C

.045, .052 Cored

 

 

T-13355-.052

.045, .052 Solid

 

 

T-15010.-.035S

.023 thru .035 Solid

 

 

(1)Can also be used for .052” wire

SWITCH REQUIREMENTS

12 Amp AC 24 Volts – Inductive

12 Amp DC 24 Volts – Inductive

S12024-1 (L.E. Part No.)

Amphenol AN3057-10 (or equiv.)

S12020-6 (L.E. Part No.)

Amphenol MS-3106A-18-11P (or equiv.)

FIGURE C.2 SWITCH REQUIREMENTS

LN-25

Page 26
Image 26
Lincoln Electric IM620-B manual Dia. Hole, Drive Roll & Guide Tube Wire Sizes Used Kit No