D-2

MAINTENANCE

D-2

 

 

 

 

1.Be sure all power to the LN-25 is shut off at the power source.

2.Check that the module mounting plate is screwed securely to the side of the gearbox.

3.Gently screw the module into the mounting plate until it just touches and stops against the rotating part inside the gearbox.

4.Back the module out 12 turn, then snug the module lock nut without rotating the module position. Do not over tighten lock nut.

CALIBRATION OF LN-25 WIRE SPEED DIAL

Calibration of the LN-25 Wire Speed dial is achieved by proper mounting of the dial knob to the speed potentiometer shaft. Whenever the knob is removed, the dial is recalibrated as follows:

NOTE: Knob set screw does not seat on shaft flat.

1.Be sure the Wire Speed potentiometer mounting nut is securely tightened, then rotate the potentiometer shaft so its flat faces about to the 100 mark on the LO range calibrated dial.

2.Set DIAL RANGE switch to LO and WIRE FEED MODE switch to CV position.

3.Press gun trigger to feed wire and measure the wire feed speed (IN/MIN) using a Portable Digital Wire Feed Speed Meter (Lincoln K283). Take at least two readings to assure repeat- able accuracy.

Feed Speed Meter (Lincoln K283). Take at least two readings to assure repeatable accuracy.

WARNING

Electrode will be electrically “hot”. Do not allow fed wire to contact any metal common with welding work.

An alternate means to measure wire feed speed is as follows:

a. Cut wire off at the end of the gun tip.

b. Press trigger to feed wire for exactly 30 seconds.

c. Cut fed wire off at the end of the gun tip and accurately measure its length.

d. Multiply the measured length by 2 to obtain the wire speed (IN/MIN).

e. Repeat above steps to assure repeatable accuracy.

4.Carefully slip speed knob onto potentiometer shaft so it points precisely to the wire speed measured in step 3, then secure the knob set screw without disturbing the position. Recheck by repeating step 3.