Lincoln Electric IM620-B manual Problems Possible Symptoms Cause, Recommended Course of Action

Models: IM620-B

1 40
Download 40 pages 40.99 Kb
Page 30
Image 30

E-2

TROUBLESHOOTING

E-2

 

 

 

 

PROBLEMS

POSSIBLE

 

(SYMPTOMS)

CAUSE

 

 

FEEDING PROBLEMS

No wire feed when gun trigger is

1.

Power source must be on

pulled

 

and open circuit

voltage

 

 

(OCV) present

at weld

 

 

terminals.

 

 

2.

LN-25 work clip may not be

 

 

connected.

 

 

3.

LN-25 polarity switch must

 

 

match electrode polarity.

 

4. Jumper plug on control or

 

 

option board may be loose

 

 

or missing.

 

 

5.

The power source O.C.V.

 

 

must be above 15 VDC. But

 

 

not more than 110 VDC.

 

6.

The gun trigger may be

 

 

faulty.- Replace gun.

Wire feeds for a short time but

1. The drive motor may be

stops feeding. When gun trigger

overloaded. Check the wire

is released and retriggered wire

feeding system. EX. Drive

feeding starts but stops again.

roll tension, reel brake and

 

gun cable liner.

Wire feeds OK, but stubs or

1.

If the power source is a

stops while welding.

 

constant current type

 

 

supply the arc voltage may

 

 

be “dipping” below 15 VDC

 

 

causing the LN-25 to stop

 

 

or hesitate.

 

2.

Connect a constant voltage

 

 

type power supply to the

 

 

LN-25.

 

3.

Make sure wire-feed mode

 

 

switch (S3) is in the proper

 

 

position.

RECOMMENDED COURSE OF ACTION

Contact your local

Lincoln Authorized

Field Service Facility

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized field service facility for technical troubleshooting assistance before you proceed.

LN-25

Page 30
Image 30
Lincoln Electric IM620-B manual Problems Possible Symptoms Cause, Recommended Course of Action