INSTALLATION

A-12

 

 

 

INSTALLING ThE OPTIONAL LAMP KIT AND AUTOMATIC START/STOP ARC SENSOR

(continued)

Roll back the rubber seals on each flexible hose joint in the arm, to allow access to the arm mechanism. Feed the 36 ft. connecting cable through the hole in the hood (Fig. 22B).

A

B

Fig. 22

Have a qualified electrician connect the 36 ft. connect- ing cable, lamp cable, and sensor cable (if used) to the control board (Fig. 23B). Snap the board onto the bottom of the remote switch (Fig. 23C). Snap the switch box (Fig. 23A) into the top of the hood by squeezing the front and back.

AC

If installing with an LTA 2.0 Telescopic Arm:

With the arm fully extended, route the 36 ft. connect- ing cable through the arm, securing it to the guide arm in two places with cable ties as shown in Figure 24. Exit the arm through the hole near the rotating hinge (Fig. 24A); use a knife to cut an X-pattern in the grom- met as shown in the inset. Loosely secure the cable to the post of the mounting bracket as shown.

4

3

B

A

 

 

C

 

2

B

1

D

 

Fig. 24

KB BK NG NB W

B

Connecting

Cable

TO:

Auto

Sensor

Fig. 23

TO:

Lamp

SF2400 STATIONARY FAN