C-1

ACCESSORIES

C-1

ALWAYS USE GENUINE LINCOLN

ELECTRIC ELECTRODES AND

VORTECH NOZZLES

Only Genuine Lincoln Electric consumables yield
the best cutting performance for the PRO-CUT 55.
The patented VORTECHnozzle provides an
extra kick of swirl as the arc exits the nozzle which
improves cutting performance. No other nozzle has
this capability or can match its performance.

GENERAL OPTIONS /

ACCESSORIES

The following options/accessories are available for
your PRO-CUT 55 from your local Lincoln Distributor.
K1600-1 Undercarriage - A valet style undercarriage
with pull-out handle for machine only. Provides Torch
and Work Cable storage.
S22147-043 - VORTECHnozzle with an .043 (1.2
mm) Orifice
S22147-068 - VORTECHnozzle with an .068 (1.7
mm) Orifice
S22149 - Electrode - replacement electrodes for cut-
ting.
S22150 - Shield Cup - This shields the torch tip and
provides more visibility to the workpiece than the drag
cup.
Note: The shield cup does not prevent the torch tip
from touching the workpiece.
S22151 - Drag Cup - The drag cup protects the torch
by preventing the torch from touching the workpiece.
K1571 Series - PCT 80 Torches come in 25 and 50
lengths in either hand held or mechanized versions.
K1678-1 MACHINE INTERFACE KIT
This kit is compatible with the present models of the
Pro-Cut 55. Machines having code numbers 10473
and 10474 may require their Output PC Board to be
upgraded to a G3326-2 board.
This kit provides the necessary hardware and instruc-
tions to install a14 Pin MS Type remote connector into
the machine. This connector provides provisions for
the following interface signals between the Pro-Cut 55
and the controller.
ARC START:
The Arc Start circuit allows for triggering of the power
source to commence cutting. This circuit can be
accessed through pins K and M of the 14 pin MS con-
nector. The circuit has a 17 VDC nominal open circuit
voltage and requires a dry contact closure to activate.
ARC INITIATED:
The Arc Initiated circuit provides information as to
when a cutting arc has transferred to the work piece.
This circuit can be accessed through pins I and J of
the 14 pin MS connector. The circuit provides a dry
contact closure when the arc has transferred. Input to
this circuit should be limited to 0.3 A for either
120VAC or 30VDC.
ARC VOLTAGE:
The Arc Voltage circuit can be used for activating a
torch height control. This circuit can be accessed
through pins D and G of the 14 pin MS connector.
The circuit provides full electrode to work arc voltage
(no voltage divider, 335VDC maximum).
Users wishing to utilize the Machine Interface can
order a K867 Universal Adapter (please adhere to the
pin locations stated above) or manufacture a 14 pin
MS connector cable assembly.
PRO-CUT 55
14-PIN BOX RECEPTACLE, FRONT VIEW
J=347
I=348
H
N
G=343
F
E
D=344
C
L
Arc Start
Arc Voltage
Arc Initiated
M=4A
K=2A