WIRING DIAGRAM (CODES 11013 & 11014)
INPUT | } | RIGHT SIDE OF MACHINE | ||
|
|
| ||
PER |
|
|
|
|
N.A. |
|
| G |
C1
1200/450 |
| |
- | + |
|
202 | 206 | 209 |
| ||
|
| |
| 205 | RELAY |
248 | ++VOLT | |
| P_XFMR | |
POWER |
| |
204 | 241 | IN_SENSE |
J10
4 | 1 | 501 |
52 502 505
63 503 506
507
J11
3 | 231A |
1 |
207A | F- | H1 H1 |
C TP1 TP3 | ||
|
| |
| D1 | B |
| INPUT | |
| BRIDGE | TP2 |
| A | |
209 | D | A |
|
|
+
1 | H1 | N | 8 | 53 | |
| H2 | ||||
5 | 12V | 3 | 56 | ||
H3 | N | ||||
2 | |||||
R | 2 | 51 | |||
| |||||
| H4 | ||||
7 | 24V | 6 | 54 | ||
H5 | R | ||||
8 | |||||
U | 9 | 64 | |||
H6 | |||||
4 | 18V | 5 62 | |||
| W | ||||
J22 |
| 18V | 4 | 61 | |
| U | ||||
|
| J21 |
| ||
| AUXILIARY |
|
| ||
| TRANSFORMER |
|
| ||
|
| T2 |
|
|
W | R | B |
|
W | V | U |
|
|
| S1 |
|
|
| POWER |
|
|
| S3 | S2 |
|
| PSI_SET | RESET |
| 277A | 277B |
|
| 223 |
| |
|
|
|
| 241 |
202 | 207A |
4 | 2 |
| 201A |
|
| ||
|
| xxxxxxx | 404 |
|
|
|
T3
CURRENT TRANSFORMER
I
| I | T1 | |
| 204 | ||
Y Y | 208 | MAIN | |
XFMR | |||
|
238
| T |
| |
U | B | ||
FR |
| ||
S | FR |
| |
| S |
|
|
|
|
|
|
| 221 | 216 |
|
|
|
|
| 61 | 62 | 64 |
| 15 | +15V | |
|
|
|
| 217 | 14 | READY LED | |||
|
|
| 18V 18V |
| |||||
|
| J5 | 1 | 2 |
| 223 | 212 | 13 | LOW_PSI LED |
| 4 | 3 | 4 |
| 218 | 12 | POT WIPER | ||
503 507 | 8 |
|
| ||||||
J1 |
|
| 213 | 11 | RESET | ||||
3 | P_XFMR |
|
|
MACHINE
H3 H1
+ C2- |
1200/450 |
6
2
| X2 | |
S |
| |
| FR | T |
|
| U |
502 506 | 2 | 6 | ++VOLT |
| 219 | 10 | GND |
501 505 | 1 | 5 | RELAY |
| 214 | 9 | THERMAL LED |
|
|
|
| 6 1 216 | 211 | 8 |
|
|
|
|
| 210 | SAFETY LED |
MACHINE
REAR OF
FAN
FAN
FAN MOTORS
X4 |
| J33 |
| R |
|
|
| |
|
|
|
|
|
| |||
XFER |
| ELEC | 3 | 1 | W |
|
|
|
| ELEC | XFER | 4 | 2 | R |
|
|
|
| X40 |
| W |
|
|
| ||
X2 |
|
|
|
|
|
| ||
|
| X20 |
|
|
|
|
| |
B21 |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
| 6 | 1 | 360 |
|
| |
| J37 |
| 7 | 2 | 365 |
|
|
|
| 1 NOZZLE |
| 8 | 3 |
| 6 | 1 |
|
| 3,8 WORK |
| 343 |
| ||||
| 5, 10 ELECTRODE | 9 | 4 | 7 | 2 | J30 | ||
|
|
| 10 | 5 | E | 8 | 3 | |
|
|
| 5 | 1 | 344 | 9 | 4 |
|
| J36 |
| G |
| ||||
|
| 6 | 2 | 54 | 10 | 5 |
| |
| 2,3 = 24V | 7 | 3 | 51 |
|
|
| |
4,8 OK TO MOVE |
|
|
| |||||
|
|
| 8 | 4 | 347 |
|
| |
|
|
| 7 | 1 | 348 | 4 |
|
|
|
|
|
|
|
| |||
| J38 |
| 8 | 2 |
| 2 |
|
|
|
|
|
|
|
| |||
| 1,7 TRIGGER | 9 | 3 | 361 |
|
|
| |
| 3,4 AIR SOL |
|
|
| ||||
| 10 | 4 |
| 366 |
|
| ||
| 5,6 ELEC SOL | 56 | 56 |
| ||||
| 11,12 = 12V | 11 | 5 | 53 | 369 | 53 |
| |
|
|
|
| |||||
| J39 |
| 12 | 6 |
| 364 |
|
|
|
| 2 | 1 |
|
|
|
| |
| 1,2 TRIGGER |
|
|
|
| |||
| J35 |
| 4 | 1 | 309 |
|
|
|
| 1 AIR SOL | 303 |
|
| ||||
| 2 ELEC SOL | 5 | 2 | 310 |
|
| ||
| 4 IGBT |
| 312 |
|
| |||
|
| 6 | 3 | 354 |
|
| ||
OUTPUT | 3 TRIGGER |
|
|
|
|
|
| |
6 GND |
|
|
|
|
|
|
| |
| L1 CHOKE |
|
|
|
|
|
| |
| xxxxxxx | S | E |
|
|
|
|
|
401
231
3
7
S | X20 | |
| FR | |
|
|
Y | J4 | 7 | 2 | 212 | 215 | 7 |
|
8 | 217 | 213 | PSI SET | ||||
Y | 3 6 CT | 3 | 211 | 6 | RESET LED | ||
|
|
|
|
|
|
201
205 BK
IN-
BK
A
S |
|
S | S |
K | T |
B | U |
| |
| K |
| B |
X3 | X30 |
X1 |
|
W |
|
X10
365 NN 360
| 2 | 5 |
| 9 | 4 | 218 | 214 | 275 |
|
404 |
| 219 | 5 | ||||||
401 | 1 | 4 | TSTAT | 10 | 5 | 210 | 215 | 276 | 4 |
|
|
|
| J2 |
|
| |||
|
| J3 |
|
|
| 223 | 3 | ||
|
|
|
|
|
| ||||
|
|
|
|
|
|
| |||
W | 8 | 16 | 7,8 ELEC SHUNT (TWIST PR) |
|
|
| 277 | 2 | |
R | 7 | 15 |
|
|
| 221 | 1 | ||
|
|
|
|
| |||||
306 | 6 | 14 |
|
|
|
|
| 275 | J40 |
X40 X4
N.C.
A | A |
| 0.6A |
| SLOW BLOW |
440- | 550- |
575V | |
460V |
|
H5 H6
S4 PRIMARY RECONNECT
241A
201
201A
208
|
| W | 5 | 13 4,5 XFER SHUNT (TWIST PR) |
|
| 276 |
| R1 |
| |
|
|
|
|
| 10K |
| |||||
|
| R | 4 | 12 | 12 GND |
|
|
|
| ||
| 312 | 11 TRIGGER |
|
| 277 |
| 2W |
| |||
| 303 | 3 | 11 |
|
|
|
|
| |||
| 3 IGBT |
|
|
| CONTROL |
| |||||
| 354 |
|
|
|
| ||||||
| 302 | 2 | 10 | 2,6 PSI SWITCH |
|
| 277A |
| POT | DISPLAY | |
| 310 |
| 1 | 9 | 10 ELEC SOL |
|
|
|
| CW (MAX) |
|
|
| 9 AIR SOL |
|
|
|
|
| ||||
| 309 |
|
|
| CONTROL | 302 | J20 |
|
|
|
|
|
|
|
|
|
| 4 | W |
|
|
| |
|
|
|
|
|
| 2 | Y |
|
| S5 |
|
|
|
|
|
|
| 1 | PRESSURE |
| |||
|
|
|
|
|
| 306 | R |
|
| WORK | |
|
|
|
|
|
| 361 |
|
| AIR | W | |
|
|
|
|
|
| 366 |
| SOLENOID |
| ||
|
|
|
|
|
| N |
| N | 4 | 2 |
|
|
|
|
|
| 550- | 7 |
| 8 |
| 369 |
|
241 | 248A |
|
| 575VAC | 6 |
| 9 |
| 364 |
| |
|
|
|
|
|
|
|
| ||||
248 |
|
|
|
|
|
|
|
|
|
| |
241A |
|
|
|
| 5 |
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
| E |
|
|
|
|
| |
231 |
|
|
|
|
|
|
|
|
|
| |
238 |
|
|
|
| 4 |
|
| 1 |
|
| |
B |
|
|
| 440- |
|
|
|
| |||
|
|
|
| 3 |
| 2 |
|
|
| ||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| 460VAC |
|
|
|
|
|
|
FRONT OF
DIAGRAMS
NOTES:
N.A. 1. FOR MACHINES SUPPLIED WITH INPUT CABLE
FOR THREE PHASE INPUT: CONNECT GREEN LEAD TO GROUND PER NATIONAL ELECTRIC CODE.
CONNECT BLACK, RED & WHITE LEADS TO SUPPLY CIRCUIT. 2. FOR MACHINES NOT SUPPLIED WITH INPUT CABLE
FOR THREE PHASE INPUT: GROUND MACHINE PER NATIONAL AND LOCAL ELECTRICAL CODES. CONNECT TERMINALS U, V & W TO SUPPLY CIRCUIT.
N.B. SINCE COMPONENTS OR CIRCUITRY OF A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTERCHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY HAVING A COMMON CODE NUMBER.
N.C. PLACE "A" LEAD ON APPROPRIATE CONNECTION FOR INPUT VOLTAGE.
LEFT SIDE OF MACHINE
OUTPUT BASE CASE FRONT PC BOARD
PROTECTIVE BONDING CIRCUIT
J40
1 15
J2,J21,
| J3 | J30,J37 |
|
1 | 8 | 1 | 5 |
9 | 16 | 6 | 10 |
|
| COLOR CODE: | |
|
| B = BLACK OR GRAY | |
J39 | G = GREEN | ||
R = RED OR PINK | |||
1 |
| ||
| W = WHITE | ||
|
| U = BLUE | |
|
| N = BROWN | |
|
|
2Y = YELLOW
J1,J20, | J4,J10, | J5,J22,J36 |
|
| |||
J33 | J35 |
|
| J38 | |||
1 | 2 | 1 | 3 | 1 | 4 | 1 | 6 |
3 | 4 | 4 | 6 | 5 | 8 | 7 | 12 |
N.D. CONNECTION SHOWN IS FOR 575V OPERATION.
CONNECTOR CAVITY NUMBERING SEQUENCE (VIEWED FROM COMPONENT SIDE OF BOARD)
ELECTRICAL SYMBOLS PER E1537
B
L12067
NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number.