MAINTENANCE | ||
|
|
|
4.Using a pair of pliers, gently tug on the pull tabs of the
5.Brush off any debris and rinse in diesel fuel.
6.
7.
8.Place the
9.Screw on the cap ring and tighten hand tight.
10.Remember to open the fuel shutoff valve before starting the engine.
WATER SEPARATOR ELEMENT
The water separator element is a two stage filter with a special filtration/water separating media, and an expanded water reservoir providing maximum protec- tion against water in the fuel. The recommended change interval for the water separator element is 1,000 hours. The procedure for changing the element is as follows:
1.Close the fuel shutoff valve located on the fuel strainer mounted to the under side of the fuel tank.
2.Rotate the quick change ring (located just below fil- ter header) clockwise approximately 1/2 turn and slide it down and off of the element.
3.Grasp the element and pull down with a slight rock- ing motion to remove the element from the grom- met post on the bottom of the filter header.
4.Slide the new element onto the grommet post on the bottom of the filter header until the element no longer easily moves up into the filter header. Now rotate the element (may take almost 1 full turn) with a slight upward pressure until the element begins to further engage the header. With the proper orientation now established apply additional pressure to seat the ele- ment in the filter header. You should feel the element “pop” into place when properly seated.
Note: The element will only go on one way. Never use excessive force when mounting the element to the header.
5.Slide the quick change ring up over the element and rotate counter clockwise until an audible click or pop is heard. If you do not hear the click you have not rotat- ed the ring far enough and the element is not in the locked position. Another indication that the ring is in the locked position is that one set (it doesn’t matter which one) of arrows located on the outside of the ring should be located directly under the air vent valve.
6.Open the fuel shutoff valve.
7.Open the air vent valve on the front of the filter head- er until fuel emerges free of air bubbles and then close the air vent valve.
Note : Consult your engine operation manual for infor- mation on air bleeding the entire fuel system