F-1

DEMO ZONE WIRING DIAGRAM

 

230V INPUT CIRCUIT

WORK CIRCUIT

 

 

 

 

 

 

 

 

50 AMP

50 AMP

 

UPPER

 

 

 

 

COPPER BAR

TO WELDING

 

 

RECEPTACLE

RECEPTACLE

TO POWER SOURCE

 

 

 

 

TABLE

 

 

 

 

WORK TERMINAL

 

 

 

 

 

 

 

4700 OHM

15uF

 

 

 

 

 

5 W

250 V

 

DEMO ZONE

40A

40A

 

 

 

DIAGRAMS

 

 

 

LOWER

 

 

 

 

COPPER BAR

 

 

N.A.

 

 

 

50 AMP

50 AMP

 

 

 

RECEPTACLE

TO POWER SOURCE

 

 

RECEPTACLE

4700 OHM

15uF

 

 

 

WORK TERMINAL

5 W

250 V

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

N.A. BOX BONDED TO GROUND

 

 

 

 

 

LEAD COLOR CODE:

 

 

 

 

 

 

B = BLACK

 

 

 

 

 

 

W = WHITE

MATERIAL: WIRE 8 AWG TYPE OR THHN OR THWN OR GAS AND OIL RESISTANT 600 V (UL)

 

 

 

 

 

G = GREEN

 

 

 

 

 

W B G

 

 

 

 

 

230 VOLT INPUT

 

 

 

 

 

 

 

TO GROUND PER

 

 

 

 

 

 

NATIONAL ELECTRIC CODE

 

 

10-2000

 

 

 

 

 

 

 

 

 

 

 

 

M19808

 

 

 

 

 

 

 

F-1

Page 18
Image 18
Lincoln Electric IM709 manual Demo Zone Wiring Diagram, Diagrams