A-3

INSTALLATION

A-3

SELECT SUITABLE LOCATION

Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and left side and out the front of the unit. A location that minimizes the amount of smoke and dirt drawn into the louvers reduces the chance of dirt accumulation that can block air passages and cause overheating.

Work Clamp Installation

Attach the work clamp per the following:

1.Unplug the machine or turn the power switch to the “OFF” position.

2.Insert the work cable terminal lug with the larger hole through the strain relief hole in the work clamp as shown in Figure A-3.

STACKING

3. Fasten securely with the bolt and nut provided.

SP-175 Plus’ cannot be stacked.

FIGURE A.3

TILTING

Strain Relief Hole

Each machine must be placed on a secure, level sur- face, or on a recommended undercarriage. The machine may topple over if this procedure is not fol- lowed.

OUTPUT CONNECTIONS

Refer to Figure A.2.

1.Work Cable Access Hole.

2.Gun Cable and Control Lead Access Hole.

3.Connector Block.

4.Gun Trigger Lead Connectors.

5.Positive (+) and negative (–) output terminals.

6.Wire Feed Gearbox and Gun Connector Block

7.Cable Clamp

8.Thumbscrew - Secures gun and cable assembly

Work Cable

Nut & Bolt

Work Clamp

Work Cable Installation

Refer to Figure A.2.

1.Open the wire feed section door on the right side of the SP-175 Plus .

2.Pass the end of the work cable that has the termi- nal lug with the smaller hole through the Work Cable Access Hole (1) in the case front.

3.Route the cable under and around the back of the Wire Feed Gearbox (6).

FIGURE A.2

WELDING AMP RANGE 25-125

5

4

SP-175 Plus

8+-

1

2

3

6

7

 

SP-175 PLUS