Lincoln Electric IM808-A Installation, Technical Specifications Power Wave 455M/STT CE K2203-2

Models: IM808-A

1 46
Download 46 pages 86 b
Page 11
Image 11

A-1

INSTALLATION

A-1

 

 

 

TECHNICAL SPECIFICATIONS - POWER WAVE 455M/STT (CE) (K2203-2)

INPUT AT RATED OUTPUT - THREE PHASE ONLY

INPUT

OUTPUT CONDITIONS

INPUT

VOLTS

AMPS / VOLTS / DUTY CYCLE

CURRENT

 

EXCEPT STT PROCESS

AMPS

 

 

 

380V - 60Hz.

400A@36V. 100%

36 A

380V - 50Hz.

400A@36V. 100%

36 A

415V - 60Hz.

400A@36V. 100%

33 A

415V - 50Hz.

400A@36V. 100%

33 A

 

STT PROCESS ALL VOLTAGES

325A@33V. 100%

OUTPUT

OUTPUT CONDITIONS

INPUT

AMPS / VOLTS / DUTY CYCLE

CURRENT

EXCEPT STT PROCESS

AMPS

 

 

500A@40V. 60%

48 A

500A@40V. 60%

48 A

500A@40V. 60%

44 A

500A@40V. 60%

44 A

STT PROCESS ALL VOLTAGES

 

325A@33V. 100%

 

 

 

OPEN

CURRENT

PULSE

PULSE

PULSE AND

STT PARAMETERS

AUXILIARY

CIRCUIT

RANGE

FREQUENCY

VOLTAGE

BACKGROUND

PEAK & BACK-

POWER

VOLTAGE

AMPS

 

RANGE

TIME RANGE

GROUND CURRENT

 

 

 

 

 

 

 

 

75 VDC

5 - 570 A

0.15 - 1000 Hz

5 - 55 VDC

100 MICRO SEC.

15-450 AMPS

40 VDC AT

 

 

 

 

-

 

10 AMPS

 

 

 

 

3.3 SEC.

 

 

 

 

 

 

 

 

220 VAC AT

 

 

 

 

 

 

5 AMPS

 

 

 

 

 

 

 

PROCESS CURRENT RANGE (DC)

MIG/MAG

FCAW

SMAW

Pulse

STT

CURRENT AMPS

50-500 A

40-500 A

30-500 A

5-750 A

40-325 A

RECOMMENDED INPUT WIRE AND FUSE SIZES

INPUT

DUTY

INPUT AMPERE

TYPE 75°C

TYPE 75°C

TYPE 75°C

COPPER WIRE

GROUND WIRE

(SUPER LAG)

VOLTAGE /

CYCLE

RATING ON

IN CONDUIT

IN CONDUIT

OR BREAKER

FREQUENCY

 

NAMEPLATE

 

AWG[IEC] SIZES

AWG[IEC] SIZES

SIZE (AMPS)

 

 

 

 

 

 

(mm2)

(mm2)

 

380V Hz.

100%

36 A

8 (10)

10 (6)

40 A

415V Hz.

100%

33 A

8 (10)

10 (6)

40 A

 

 

 

 

 

 

PHYSICAL DIMENSIONS

HEIGHT

WIDTH

DEPTH

WEIGHT

663 mm

505 mm

835 mm

121 kg.

(26.10 in)

(19.86 in)

(32.88 in)

(267 lbs.)

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to 40°C

STORAGE TEMPERATURE RANGE

-40°C to 40°C

POWER WAVE 455M/STT (CE)