A-7

INSTALLATION

A-7

 

 

 

Connection of LN-742 and Cobramatic to RANGER 305D (CE)

Shut the welder off.

Connect per instructions on the appropriate connec- tion diagram in Section F.

Connection of PRINCE XL SPOOL GUN to the

RANGER 305D (CE)

Connection of the Prince XL Spool Gun requires the use of the K1849-1 Adapter Module.

Shut the Welder off.

For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.

Connect the Control Cable of the Spool Gun to the Adapter Module and connect the Control Cable of the Adapter Module to the Welder.

Connect the Gas Hose.

Set the MODE switch to the "CV-WIRE " position.

Set the "WELD TERMINALS" switch to "WELD

TERMINALS ON".

Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

Set the “IDLE” switch to the “HIGH” position.

RANGER 305D (CE)

Page 19
Image 19
Lincoln Electric IM837-A manual Connection of LN-742 and Cobramatic to Ranger 305D CE, Connection of Prince XL Spool GUN to