Lincoln Electric IM909 manual Additional Output Capacity, Recommended Input Wire and Fuse Sizes

Models: IM909

1 46
Download 46 pages 29.39 Kb
Page 11
Image 11

A-2

 

 

INSTALLATION

A-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT - IEC 60974-1 (K1834-3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duty Cycle-Applications

 

 

 

 

Volts at Rated Amperes

 

 

Amps

 

40%

 

 

 

 

 

 

 

 

 

AC/DC Stick / Balance TIG

 

 

35.0

 

 

375

 

 

Unbalance (70% Penetration#) AC TIG

 

 

24.0

 

 

350

 

 

60%

 

 

 

 

 

 

 

 

 

AC/DC Stick / Balance TIG

 

 

34.0

 

 

350

 

 

Unbalance (70% Penetration#) AC TIG

 

 

23.0

 

 

325

 

 

100%

 

 

 

 

 

 

 

 

 

AC/DC Stick / Balance TIG

 

 

32.0

 

 

300

 

 

Unbalance (70% Penetration#) AC TIG

 

 

21.0

 

 

275

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADDITIONAL OUTPUT CAPACITY

Output Current

Range

2Amps DC

to

420Amps AC-DC*

Maximum Open

Circuit Voltage

(STICK AND TIG)

AC/DC OCV: 80

Type of Output

CC(Constant Current) AC/DC (GTAW) Stick (SMAW)

Auxiliary Power

15Amp Circuit Breaker and NEMA 5-15R Duplex

Receptacle for up to:

115VAC 8 Amp Auxiliary Power Receptacle

115VAC 5 Amp weld Switched Cooler Receptacle

5 Amp Circuit Breaker and grounded 220VAC Euro(Schuko) receptacle

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For all Stick, DC TIG, and Balanced AC TIG Welding

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Unbalanced AC TIG Welding Above 275 Amps:

 

 

 

 

at 375A/40% Duty Cycle with out Standard Power

 

 

350A/40% Duty Cycle, Auto-Balance Penetration with

 

 

 

 

 

 

Factor Correction Capacitors

 

 

out Standard Power Factor Correction Capacitors

 

 

 

 

Based on the 1999 U.S. National Electrical Code

 

 

Based on the 1999 U.S. National Electrical Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

Type 75°C

Type 75°C

 

 

 

 

 

 

 

Type 75°C

 

 

Type 75°C

 

 

Input

Fuse

 

Ampere

 

Copper Wire in

Copper

 

 

Fuse

 

 

Input

 

Copper Wire in

 

 

Copper

 

 

Voltage /

(Super Lag)

 

Rating

 

Conduit AWG

Ground Wire in

 

 

(Super Lag)

 

 

Ampere

 

Conduit AWG

 

 

Ground Wire in

 

 

phase/

or Breaker

 

Rating on

 

(IEC) Sizes

Conduit AWG

 

 

or Breaker

 

 

Rating

 

(IEC) Sizes

 

 

Conduit AWG

 

 

 

 

40°C (104°F)

 

 

 

 

 

40°C (104°F)

 

 

 

 

Frequency

Size1

 

Nameplate

 

Ambient

(IEC) Sizes

 

 

Size1

 

 

 

 

Ambient

 

 

(IEC) Sizes

 

 

220-230/1/50/60

150

 

119

 

3 (26.7 mm2)

6 (13.3 mm2)

 

 

150

 

 

118

 

3 (26.7 mm2)

 

 

6 (13.3 mm2)

 

 

380-400/1/50/60

110

 

69

 

4 (21.2 mm2)

6 (13.3 mm2)

 

 

110

 

 

68

 

4 (21.2 mm2)

 

 

6 (13.3 mm2)

 

 

415/1/50/60

 

110

 

63

 

4 (21.2 mm2)

6 (13.3 mm2)

 

 

110

 

 

62

 

4 (21.2 mm2)

 

 

6 (13.3 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

Height

Width

Depth

Weight

 

 

31.0 in.

22.0 in.

26.0 in.

507 lbs.

 

 

787 mm

559 mm

660 mm

230 kgs.

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

STORAGE TEMPERATURE RANGE

-20°C to +40°C (-04° to +104°F)

-40°C to +85°C (-40° to +185°F)

 

 

TRANSFORMER INSULATION CLASS 180°C (H)

 

 

 

1ALSO CALLED ‘INVERSE TIME" OR "THERMAL/MAGNETIC " CIRCUIT BREAKERS; CIRCUIT BREAKERS WHICH HAVE A DELAY IN TRIPPING ACTION THAT DECREASES AS THE MAGNITUDE OF CURRENT INCREASES.

*50/60HZ IEC Max. range exceeds 310A.