Lincoln Electric IM919 manual Welding Controls, Weld Mode Selector Switch, Arc Control, Operation

Models: IM919

1 49
Download 49 pages 39.64 Kb
Page 19
Image 19
WELDING CONTROLS:

B-2

OPERATION

B-2

 

 

15

 

1

14

 

 

 

 

13

 

2

12

 

 

3

4

WELDING CONTROLS:

1. OUTPUT CONTROL: The CONTROL dial provides continuous control of the welding current or welding voltage depending on the selected welding mode. This control is not active in the CC-STICK, DOWN HILL PIPE, and CV-WIRE modes when a remote control or wire feeder with remote control is connected to either the 6 pin or 14 pin Amphenol.

2. WELD MODE SELECTOR SWITCH:

(Provides four selectable welding modes)

CV-WIRE DOWN HILL PIPE CC-STICK TOUCH START TIG

3. ARC CONTROL :

The ARC CONTROL WIRE/STICK dial is active in the WIRE, STICK and DOWN HILL PIPE modes, and has different functions in these modes. This control is not active in the TIG mode.

11

10

9

8

7

6

5

CC-STICK mode: In this mode, the ARC CONTROL dial sets the short circuit current (arc-force) during stick weld- ing to adjust for a soft or crisp arc. Increasing the number from -10(soft) to +10(crisp) increases the short circuit cur- rent and prevents sticking of the electrode to the plate while welding. This can also increase spatter. It is recom- mended that the ARC CONTROL be set to the minimum number without electrode sticking. Start with a setting at 0.

DOWNHILL PIPE MODE: In this mode, the ARC CON- TROL dial sets the short circuit current (arc force) during stick welding to adjust for a soft or a more forceful digging arc (crisp). Increasing the number from -10(soft) to +10(crisp) increases the short circuit current which results in a more forceful digging arc. Typically a forceful digging arc is preferred for root and hot passes. A softer arc is pre- ferred for fill and cap passes where weld puddle control and deposition (“stacking” of iron) are key to fast travel speeds. It is recommended that the ARC CONTROL be set initially at 0.

CV-WIRE mode: In this mode, turning the ARC CONTROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance control. The proper setting depends on the pro- cedure and operator preference. Start with a setting at 0.

RANGER® 250

Page 19
Image 19
Lincoln Electric IM919 manual Welding Controls, Weld Mode Selector Switch, Arc Control, Operation