Section A

Installation

Technical Specifications

Wire Capacity

.030" - .045" (0.6mm - 1.2mm) solid and hard wire

.030" - 1/16" (0.8mm - 1.6mm) aluminum and cored wire

Wire Speed

800 IPM (20.3 mpm) Max. at rated feeder Input Voltage (120VAC / 42VAC)

Duty Cycle - 100% (All ratings are using Argon Gas)

200 Amps/25 Volts

Air cooled standard

 

Shipping Weight (approximate) - Air Cooled

 

15ft. (4.5m)

13.09 lbs. (5.94 Kg)

25ft.

(7.6m)

19.29 lbs. (8.29

Kg)

50ft.

(15.2m)

29.9 lbs. (13.19

Kg)

Torch weight (less leads)

Air/Water cooled - 2.5 lbs. (1.13 kilogram)

Support Equipment Required

C.V. or C.C. Power Source of suffi cient capacity for your needs.

Regulated gas supply and hoses.

Properly sized power leads from power source to wire feeder and ground.

Gun Lead Connections

Power Cable

A #2 AWG power cable is used on the Python-Plus. The gun end of the cable has a fitting crimped to the copper cable strands. This fitting is then threaded into the gun body. The cabinet end of the power cable is incorporated into the Power/Gas Adaptor.

Conduit

The Python-Pluscomes standard with a poly-lined conduit, for feeding aluminum wire. The longer fitting with a shallow groove is used on the gun end. A set screw located on top of the gun handle secures the conduit in place. The cabinet end of the conduit is incorporated into the Power/Gas Adaptor.

Gas Hose

The gas hose is pushed over a barbed fi tting on the gun body and secured with a plastic tie wrap. The cabinet end of the gas hose is incorporated into the Power/Gas Adaptor.

Electric Cable

A multi-conductor control cable is used on the Python-Plus. The gun end of the cable is secured with a cable clamp and the wires are connected to the potentiometer, the micro switch, the motor and the gun body mechanically. Slack is left in the electric cable as it exits the back of the gun to prevent cable and/or wire breakage. The cabinet end of the control cable uses a 7-Pin, Amphenol connector.