A-2

INSTALLATION

A-2

Read entire installation section before starting installation.

SAFETY PRECAUTIONS

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should perform this installation.

Only personnel that have read and understood the POWER MIG 215 Operating Manual should install and operate this equip- ment.

Machine must be grounded per any national, local or other applic- able electrical codes.

The POWER MIG power switch is to be in the OFF position when installing work cable and gun and when connecting other equip- ment.

UNCRATING THE POWER MIG 215

Cut banding and lift off cardboard carton. Cut banding holding the machine to the skid. Remove foam and corrugated packing material. Untape accessories from Gas Bottle Platform. Unscrew the two wood screws (at the Gas Bottle Platform) holding the machine to the skid. Roll the machine off the skid assembly.

LOCATION

Locate the welder in a dry location where there is free circulation of clean air into the louvers in the back and out the front. A location that minimizes the amount of smoke and dirt drawn into the rear louvers reduces the chance of dirt accumulation that can block air pas- sages and cause overheating.

INPUT POWER, GROUNDING AND CONNECTION DIAGRAMS

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

All input power must be electrically dis- connected before proceeding.

1.Before starting the installation, check with the local power company if there is any question about whether your power supply is adequate for the volt- age, amperes, phase, and frequency specified on the welder nameplate. Also be sure the planned installation will meet the U.S. National Electrical Code and local code requirements. This welder may be operated from a single phase line or from one phase of a two or three phase line.

2.Models that have multiple input voltages specified on the nameplate (e.g. 208/230) are shipped con- nected for the highest voltage. If the welder is to be operated on lower voltage, it must be reconnected according to the instructions in Figure A.1 for dual voltage machines.

WARNING

Make certain that the input power is electrically disconnected before removing the screw on the reconnect panel access cover.

------------------------------------------------------------------------

POWER MIG 215

Page 10
Image 10
Lincoln Electric pmn Safety Precautions, Uncrating the Power MIG, Location, Input POWER, Grounding and Connection Diagrams

pmn specifications

Lincoln Electric is a prominent name in the world of welding and cutting solutions, and its PMN (Precision Manufacturing Network) division is a testament to the company's commitment to innovation and quality in manufacturing processes. The PMN is designed to provide high-performance solutions for diverse industrial applications, focusing on precision, productivity, and advanced technology.

One of the main features of the Lincoln Electric PMN is its integrated approach to manufacturing, which combines traditional fabrication techniques with cutting-edge automation. This enables the PMN to produce high-quality parts with improved accuracy and efficiency. The use of advanced robotics and automation systems allows for minimal human intervention, reducing the risk of errors and enhancing the overall reliability of the production process.

Another significant characteristic of the PMN is its dedication to lean manufacturing principles. By streamlining workflows and minimizing waste, Lincoln Electric ensures that production times are reduced while maintaining high quality. This lean approach not only enhances productivity but also reduces costs, allowing businesses to achieve better profit margins.

The PMN also focuses on the integration of advanced technologies such as artificial intelligence and machine learning in its manufacturing processes. These technologies enable the prediction of maintenance needs and optimization of operating parameters, leading to enhanced equipment longevity and reduced downtime. The data analysis capabilities provided by AI tools help in refining processes and improving product quality consistently.

In terms of product offerings, the Lincoln Electric PMN specializes in custom manufacturing solutions tailored to meet specific client requirements. This adaptability makes it suitable for various industries, including automotive, aerospace, and energy. The PMN is equipped to handle complex projects, providing seamless integration from design and prototyping to final production.

Furthermore, Lincoln Electric's commitment to sustainability is evident in the PMN's practices. The emphasis on energy-efficient processes and the use of recyclable materials underlines the company's goal of reducing the environmental footprint while delivering top-notch manufacturing services.

In summary, Lincoln Electric's Precision Manufacturing Network represents the confluence of tradition and technology. Its focus on precision manufacturing, lean principles, automation, and sustainability ensures that it remains a leader in the competitive landscape of manufacturing solutions. The PMN stands out as a model for efficiency and innovation, catering to a wide array of industrial needs.