TROUBLESHOOTING | ||
|
|
|
| Observe all Safety Guidelines detailed throughout this manual |
|
PROBLEMS | POSSIBLE AREAS OF | |
(SYMPTOMS) | MISADJUSTMENT(S) | |
|
| OUTPUT PROBLEMS |
Major physical or electrical damage | None | |
is evident. | Contact your local Authorized Field | |
| Service Facility. | |
|
|
|
No wire feed, weld output or gas | 1. | Make sure correct voltage is |
flow when gun trigger is pulled. Fan |
| applied to the machine (115vac). |
does NOT operate. |
|
|
| 2. | Make certain that power switch |
|
| is in the ON position. |
| 3. | Make sure circuit breaker is |
|
| reset. |
|
|
|
No wire feed, weld output or gas | 1. | The thermostat may be tripped |
flow when gun trigger is pulled Fan |
| due to overheating. Let machine |
operates normally. |
| cool. Weld at lower duty cycle. |
| 2. | Check for obstructions in air |
|
| flow. Check Gun Trigger connec- |
|
| tions. See Installation section. |
RECOMMENDED COURSE OF ACTION
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln Authorized Field Service Facility.
3. Gun trigger may be faulty.
CAUTION