INSTALLATION
TECHNICAL SPECIFICATIONS - SA-250
|
|
|
|
|
| INPUT - DIESEL ENGINE |
|
| |
Manufacturer |
| Description |
| Speed | Displacement | Ignition | Capacities | ||
Perkins |
| 3 cyl., 4 cycle |
| 1725 RPM | 152 cu. in. | Electric | Fuel: 15 gal. | ||
D3.152 |
|
| Full load | (2500 cc) |
| (57 liters) | |||
|
| diesel |
|
|
|
|
| ||
|
| 38.2 HP @ |
| 1800 RPM |
|
| Oil: 7.2 qt. | ||
|
| 1725 RPM |
| High idle |
|
| (6.9 liters) | ||
|
|
|
|
|
| 1350 RPM |
|
| Water/coolant: 10 qt. |
|
|
|
|
|
| Low idle |
|
| (9.5 liters) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| RATED OUTPUT - WELDER |
|
| |
Duty Cycle |
|
| Amps | Volts at Rated Amperes | |||||
100% Duty Cycle |
|
| 200 DC Constant Current |
| 40V | ||||
60% Duty Cycle |
|
| 250 DC Constant Current |
| 40V(1) | ||||
35% Duty Cycle |
|
| 325 DC Constant Current |
| 33V | ||||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
|
| OUTPUT - WELDER AND GENERATOR |
| |||||
Welding Ranges | Max. Open Circuit Voltage | Auxiliary Power | |||||||
| 98.5 | 3.0 kVA of 115/230 V, 60Hz Power | |||||||
|
|
|
|
|
|
|
| 26 Amps @ 115 V(2) | |
|
|
|
|
|
|
|
| 13 Amps @ 230 V | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| PHYSICAL DIMENSIONS |
|
| |
Height |
|
|
|
| Width | Depth |
| Weight | |
43.1 in. |
|
|
|
| 28 in. | 67 in. |
| 1650 lb. | |
1096 mm |
|
|
|
| 711 mm | 1702 mm |
| 742.5 kg | |
|
|
|
|
|
|
|
|
|
|
1Lincoln rating. Nema rating at 60% duty cycle is 250 amps @ 30 V.
215 amps can be drawn from either half of the receptacle. Total combined load of all receptacles cannot exceed 3.0 kVA.