INSTALLATION

TECHNICAL SPECIFICATIONS - SA-250

 

 

 

 

 

 

INPUT - DIESEL ENGINE

 

 

Manufacturer

 

Description

 

Speed

Displacement

Ignition

Capacities

Perkins

 

3 cyl., 4 cycle

 

1725 RPM

152 cu. in.

Electric

Fuel: 15 gal.

D3.152

 

Water-cooled

 

Full load

(2500 cc)

 

(57 liters)

 

 

diesel

 

 

 

 

 

 

 

38.2 HP @

 

1800 RPM

 

 

Oil: 7.2 qt.

 

 

1725 RPM

 

High idle

 

 

(6.9 liters)

 

 

 

 

 

 

1350 RPM

 

 

Water/coolant: 10 qt.

 

 

 

 

 

 

Low idle

 

 

(9.5 liters)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT - WELDER

 

 

Duty Cycle

 

 

Amps

Volts at Rated Amperes

100% Duty Cycle

 

 

200 DC Constant Current

 

40V

60% Duty Cycle

 

 

250 DC Constant Current

 

40V(1)

35% Duty Cycle

 

 

325 DC Constant Current

 

33V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT - WELDER AND GENERATOR

 

Welding Ranges

Max. Open Circuit Voltage

Auxiliary Power

40-325 Amps DC

 

98.5

3.0 kVA of 115/230 V, 60Hz Power

 

 

 

 

 

 

 

 

26 Amps @ 115 V(2)

 

 

 

 

 

 

 

 

13 Amps @ 230 V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

Height

 

 

 

 

Width

Depth

 

Weight

43.1 in.

 

 

 

 

28 in.

67 in.

 

1650 lb.

1096 mm

 

 

 

 

711 mm

1702 mm

 

742.5 kg

 

 

 

 

 

 

 

 

 

 

1Lincoln rating. Nema rating at 60% duty cycle is 250 amps @ 30 V.

215 amps can be drawn from either half of the receptacle. Total combined load of all receptacles cannot exceed 3.0 kVA.

SA-250

Page 8