F-46

F-46

TROUBLESHOOTING & REPAIR

ABNORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

(HIGH CV MODE)

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

OUTPUT CAPACITOR BANK NOT FUNCTIONING

0 volts

50 volts

5 ms

This is NOT the typical CV output voltage waveform. The capacitor bank is not functioning. Note the “ripple” in the waveform. The capac- itor bank was disconnected to simu- late an open or non-functioning capacitor bank. Each vertical divi- sion represents 50 volts and each horizontal division represents 5 mil- liseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

RANGER 300 D AND 300 DLX