TOC

TOC

G-2

ELECTRICAL DIAGRAMS

WIRING DIAGRAM - LN-10 (CONTROL)

 

G-2

 

554 551 552 553

512A

500

 

 

1 2

3

4

5

6

7

8

 

 

J11**

 

 

 

 

 

 

 

DISPLAY

 

 

 

P.C. BOARD

 

500 H

 

F D E A B

C

**

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8 9 J10

 

 

ELECTRICAL SYMBOLS PER E1537.

CAVITY NUMBERING SEQUENCE

 

**

PIN NUMBERING SEQUENCE

 

 

 

 

(COMPONENT SIDE OF P.C. BOARD)

 

(COMPONENT SIDE OF P.C. BOARD)

 

 

1

5

1

3

1 2

 

1

5

J17

 

 

J10 8

1

 

 

 

J8

 

J3

 

J1

J6

 

 

 

 

 

J11

 

 

 

 

 

 

 

 

J4

 

 

 

PIN 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

10

4

6

3 4

 

6

10

***

CONNECTOR CAVITY

 

 

 

 

1

7

1

6

J2 1

4

 

 

 

 

J5

 

NUMBERING SEQUENCE

 

 

 

 

 

J7

 

 

 

 

 

 

(NON LEAD SIDE OF CONNECTOR)

J19***

 

8

14

7

12

5

8

 

 

 

 

 

 

 

 

 

1

1

U

2

CASE

 

 

 

 

 

 

 

P10

 

 

 

 

GROUNDING

GROUNDING

 

LEAD COLOR CODING

 

 

 

 

P17

J19

P19

 

LEAD

STUD

 

B - BLACK

 

 

 

P11

PIN 1

 

PROTECTOR

 

 

R - RED

 

 

 

 

 

PIN 1

2

2

U

1 P19***

 

 

W - WHITE

 

 

 

 

 

 

 

 

 

 

 

 

 

U - BLUE

 

 

 

 

 

 

 

 

 

 

W

 

CONTROL P.C BOARD

 

 

 

 

 

 

 

 

 

ARC

 

 

 

 

 

 

 

 

 

 

CURRENT

 

 

 

 

 

 

 

 

 

 

SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return to Section

to Section TOC

Return to Master TOC

to Master TOC

ENCODERPC

J17**

1

4

 

 

2

 

 

3

BOARD

 

5

 

6

 

 

7

VOLTS

8

ENCODER

 

1

 

3

 

 

2

PC

J17**

4

 

BOARD

 

5

 

6

 

 

7

 

WFS

8

 

KEYPAD

 

500

A

B

C

505

 

 

 

517

 

 

E

516

D

 

505

 

 

500

 

 

 

 

 

 

F

527

 

 

H

526

 

G

 

 

 

OPTIONAL REMOTE

 

CONTROL KIT

A

 

 

B

 

C

 

D

500

C

B

A

E

D

F

H

G

J15

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.A., N.B.

 

 

 

N.B.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

*

 

 

 

 

*

 

 

 

 

*

 

*

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J8

 

 

 

 

 

J1

 

 

 

 

J2

 

 

 

 

 

J3

 

 

J4

 

 

 

 

 

 

J5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J7

 

 

 

 

 

 

 

 

 

1 2

3

4

 

1 2

3

4

5

6

7

8

1 2

3

4

5

6

1 2

3

4

1 2

3

4

5

6

7

8

9 1011121314

1 2

3

4

5

6

7

8

9 10

 

1 2

3

4

5

6

7

8

9 101112

1 2

3

4

5

6

7

8

9 10

 

 

W W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 4 67 21 77

 

U U W W

J18

526 500 505 517 527 516

512 552 500 551 553 554

500 512B 81R 82R

512 500

FAULT

 

CR1-

 

GAS SOLENOID(ROBOT)

TRIGGER(ROBOT)

COLD FEED FWD. (ROBOT) COLD FEED REV. (ROBOT) BURN BACK(ROBOT) ANALOG COMMON(ROBOT) WFS(ROBOT) VOLTS(ROBOT)

 

 

POWER SUPPLY FAIL (ROBOT)

ARC DETECT (ROBOT)

+5VDC(ROBOT)

 

 

 

 

 

B 512 U

519 R

522 560 539 561 541 520

542 500 76

 

75

 

BRIDGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

542

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R AC

AC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

R

 

 

 

 

 

 

 

 

 

 

 

 

 

500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R.F. TOROID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ASSEMBLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND 77 76 75 21

 

 

41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 2

42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

561 560

520

519

522 512

67

B

R U

541

539

 

H

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J13 J

I

 

M E

D C

N

L K H G

F

 

B

A

 

 

 

 

 

 

 

 

512B

500 81R 82R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I J12GFE

D C

(42)B

(41)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WIRE DRIVE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECEPTACLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B C D

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECEPTACLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Return

to Section TOC

Return

to Master TOC

NOTES:

N.A. THE JUMPER PLUG (SHOWN), THE OPTIONAL REMOTE SWITCH INTERFACE MODULE (NOT SHOWN), OR THE OPTIONAL ROBOTIC INTERFACE MODULE (NOT SHOWN) MUST BE INSTALLED INTO CONNECTOR J5 ON THE CONTROL P.C. BOARD FOR THE LN-10 TO OPERATE.

N.B. THE OPTIONAL ROBOTIC INTERFACE MODULE MOUNTS IN CONNECTORS J5 AND J6.

CABLE TO

WIRE DRIVE

 

A

539

SHIELDED

B

541

F

U

CABLE

G

R

A

H

B

 

K

 

 

L

 

 

N

67

SHIELDED

C

512

D

522

CABLE

E

519

B

M

520

 

CONTROL

I

W

J

W

CABLE

TO MOTOR

TO MOTOR

TO MOTOR TACHOMETER

TO MOTOR TACHOMETER

TO MOTOR TACHOMETER

TO BRASS BLOCK VOLTAGE SENSE TO SOLENOID

TO SOLENOID

TO DUAL PROCEDURE SWITCH TO DUAL PROCEDURE SWITCH TO TRIGGER

TO TRIGGER

21 67

FOR CONNECTION TO ROBOTICS INTERFACE HARNESS

4-24-98

Return

Return

L10218-1

NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The wiring diagram specific to your code is pasted inside one of the enclosure panels of your machine.

LN-10

Page 90
Image 90
Lincoln Electric SVM154-A service manual Electrical Diagrams, Wiring Diagram LN-10 Control

SVM154-A specifications

The Lincoln Electric SVM154-A is a powerful and versatile inverter-based welding machine designed for a wide range of applications. As a part of Lincoln Electric's esteemed portfolio, this model is particularly favored for its robust performance and cutting-edge technologies, making it ideal for both professional fabricators and hobbyists alike.

One of the standout features of the SVM154-A is its compact and lightweight design, which enhances portability without compromising power. Weighing significantly less than traditional welding machines, it allows welders to easily transport the equipment to various job sites. This feature is particularly beneficial in industries where mobility is essential.

Equipped with advanced inverter technology, the SVM154-A delivers a stable and smooth arc, providing consistent welding performance even in challenging conditions. The inverter design also contributes to energy efficiency, allowing users to save on operational costs while enjoying superior performance. The machine supports both MIG and TIG welding processes, which adds to its versatility. This adaptability makes it suitable for a range of materials including mild steel, stainless steel, and aluminum.

Another notable characteristic is its user-friendly interface. Designed with the welder in mind, the SVM154-A includes intuitive controls that simplify settings adjustments and operational processes. This ergonomic layout allows for ease of use, even for beginners, while still offering the adjustments that experienced welders appreciate for customizing their welds.

The SVM154-A also includes several safety features, such as thermal overload protection and a dynamic power control, ensuring safe operation while maintaining high productivity. Users benefit from features that protect both the machine and the operator, making it a reliable choice for long hours of work.

Moreover, Lincoln Electric's commitment to durability is evident in the SVM154-A's construction. Built with high-quality materials, this welding machine is designed to withstand the rigors of daily use, ensuring longevity and reliability over time.

In summary, the Lincoln Electric SVM154-A stands out for its portability, versatility, and user-centric design. With advanced inverter technology that promotes energy efficiency and a stability for various welding processes, it serves as a valuable tool for both professionals and hobbyists seeking to achieve high-quality welds across different applications. Its combination of advanced features, safety mechanisms, and rugged durability positions the SVM154-A as a top choice in the welding equipment market.