TECHNICAL SPECIFICATIONS - PRECISION TIGĀ® 225 (K2533-1AND K2535-1,-2)
Weld Voltage(NEMA)
15.7 V AC/DC
15.2 V AC/DC
14.1 V AC/DC
14.0 V AC/DC
29.0 V AC/DC
27.2 V AC/DC
23.4 V AC/DC
Typeof Output
CC (Constant Current)
AC/DC
Weld Current*
225AAC/DC
180AAC/DC
90AAC/DC (BAL.)
80AAC (AUTO-BAL.)
225AAC/DC
180AAC/DC
90AAC/DC
Maximum Open
Circuit Voltage
(STICKAND TIG)
AC OCV: 75
DC OCV: 66
Input Current at Rated Output
42A / 39A Effective
and 94A / 85A Maximum
Process Duty Cycle**
GTAW
10% Duty Cycle
20% Duty Cycle
100% Duty Cycle
SMAW
10% Duty Cycle
20% Duty Cycle
100% Duty Cycle
Output Current
Range
5-230 Amps (AC)
5-230 Amps (DC)
Standard Voltage
208/230/1/60
Power Factor
0.62 Min.
Idle Current
3.0A/2.7A Max.

INPUT - SINGLE PHASE ONLY

OUTPUT RANGE

RATED OUTPUT

**Chart gives max. rated Output Amps @% Duty Cycle (Based on a 10 minute cycle).
(Example; 180A@20% for AC/DC Stick andTIG)
* Inputs and ratings include a 20 amp rated load on the 115vacreceptacle.

AC/DC Stick and Auto-B alance TIG Output L imits

1
Using provided input cable for protected
2
input supply
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
50 70 90 110 130 150 170 190 210 230
Output Amps
Output Duty Cycle
AC/DC Stick & Bal.TIG
with Max. Aux.load or
Auto-B al. T IG w/ o Aux.
AC Auto -Bal. TIG with
Max. Aux. Load
1OutputLimits allow for continuous max. rated load on 115vac auxiliary receptacle.
2Wiringand protection based on the 2005 U.S. National Electric Code.
Usea Super Lag type fuse or circuit breaker with a delay in tripping action.
Modelswith NEMA 6-50P plug may be used with a 50 amp protected 6-50R receptacle, or with a maximum 70 amp protected 6-50R
receptacleif dedicated for the welder.