INSTALLATION
A-6 A-6
PRECISION TIG® 225
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC

INPUT RECONNECT PROCEDURE

Onmultiple input voltage welders, be sure the machine
is connected per the following instructions for the volt-
age being supplied to the welder.
Failure to follow these instructions can cause
immediatefailureofcomponentswithinthewelder
and void machineʼs warranty.
-----------------------------------------------------------------------
Multiplevoltagemodelsareshipped connected for
the highest voltage. To change this connection
refer to the following instructions.
ELECTRIC SHOCK can kill.
• Turnthe input power OFF at the dis-
connect switch or fuse box before
working on this equipment.
------------------------------------------------------------------------
For the lowest rated voltage connection (Refer to figure A.1):
1. Remove the sheet metal left side cover.
2. Disconnect lead H3 from the power switch and insu-
late with the insulation from the H2 lead.
3. Connect lead H2 to the power switch where H3 was
connected.
4. Tighten connections.
5. Replace sheet metal cover and all screws
For the highest rated voltage connection (Refer to Figure A.1):
The machine is normally shipped connected for the
highest rated voltage, however verify the following:
1. Remove the sheet metal left side cover.
2. Disconnect lead H2 from the power switch and insu-
late with the insulation from the H3 lead.
3. Connect lead H3 to the line switch where H2 was
connected.
4. Tighten connections.
5. Replace sheet metal cover and all screws.

CONNECTIONS FOR TIG (GTAW)WELDING

TIG TORCH CONNECTION
Refer to Included Equipment in the Operation
Section of this manual for TIG welding equipment
which is included with the PRECISION TIG® 225.
CAUTION
WARNING

FIGUREA.1ReconnectLeads

INPUTLEADSINPUT LEADS
L1& L2L1 & L2
LEADH1LEAD H1
(DONOT(DO NOT
REMOVE)REMOVE)
FORLOWEST RATED VOLTAGEFOR LOWEST RATED VOLTAGE
:H2 CONNECTED : H2 CONNECTED
FORHIGHEST RATED VOLTAGEFOR HIGHEST RATED VOLTAGE
:H3 CONNECTED : H3 CONNECTED
BACKVIEW OF LINE SWITCHBACK VIEW OF LINE SWITCH
OUTPUTCONNECTIONS
FIGUREA.2LocationofOutputConnections
ELECTRODE/GAS
OUTLET
RECEPTACLE
(TWIST-MATE)
WORKCABLE & CLAMP