TROUBLESHOOTING AND REPAIR

F-6

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

 

RECOMMENDED

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

 

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

Machine regularly over heats -

Machine regularly over heats - ther-

1.

The thermostat(s) may be

 

thermostat opens. Yellow light on

mostat opens. Yellow light on front

 

faulty. Check or replace.

 

front panel glows. The fan runs

panel glows. The fan runs but the

 

 

 

but the machine has no output.

machine has no output.

2.

The control board may be

 

 

 

 

 

faulty.

 

 

 

 

 

The machine does not have output

The machine does not have output

1.

Check the Stick/TIG switch(S3)

in the Stick mode. The machine

in the Stick mode. The machine

 

and associated leads. See

 

operates correctly in the TIG mode.

operates correctly in the TIG mode.

 

wiring diagram.

 

 

 

 

2. The control board may be

 

 

 

 

 

faulty.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.