TROUBLESHOOTING AND REPAIR | |||||
|
| ||||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
|
| ||
|
|
|
|
|
|
| PROBLEMS | POSSIBLE AREAS OF |
| RECOMMENDED |
|
| (SYMPTOMS) | MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
|
Machine regularly over heats - | Machine regularly over heats - ther- | 1. | The thermostat(s) may be |
| |
thermostat opens. Yellow light on | mostat opens. Yellow light on front |
| faulty. Check or replace. |
| |
front panel glows. The fan runs | panel glows. The fan runs but the |
|
|
| |
but the machine has no output. | machine has no output. | 2. | The control board may be |
| |
|
|
|
| faulty. |
|
|
|
|
| ||
The machine does not have output | The machine does not have output | 1. | Check the Stick/TIG switch(S3) | ||
in the Stick mode. The machine | in the Stick mode. The machine |
| and associated leads. See |
| |
operates correctly in the TIG mode. | operates correctly in the TIG mode. |
| wiring diagram. |
| |
|
|
| 2. The control board may be |
| |
|
|
|
| faulty. |
|
|
|
|
|
|
|
CAUTION