B-6

OPERATION

B-6

 

 

 

SET UP MENU

Many additional parameters can be modified via the Set Up Menu. To access the Set Up Menu:

Position the ON/OFF switch to OFF “0”.

Depress and hold the Parameter select Push Button.

Position the On/Off switch to on "I" at the back of the machine; the input voltage light "Item 1" (green LED) confirms normal operation.

The SETUP mode is confirmed by a center "0" on the Digital display “Item 6”.

-Rotate the Output / Parameter Adjust Knob, the Digital Display shows the numbers corre- sponding to the parameters in sequence; stop at the desired parameter and push the "Setup/Parameter Push Button".

-The number on the Digital display "Item 6" is replaced by the value of the parameter that can be modified through the Output / Parameter adjust knob "Item 5".

-With parameter (9) all the modifications made in the SETUP mode are cancelled and the standard values set by Invertec V205-T AC/DC are restored.

-To exit the Set Up Menu, return to “0” and press the Setup/Parameter Push Button

INDICATOR

PARAMETER

DEFAULT

 

 

 

 

0

Exit From Set Up

 

 

1

Not Used

 

 

2

Pre Flow Time (0 - 25 seconds)

0.5 sec.

3

Arc Force, percent above Peak Current for Stick only (0 - 100%)

30%

 

4

Hot Start, percent above Peak Current for Stick only (0 - 100%)

80%

 

5

Setting of AC wave Form

2 (Square)

 

0 = Sinusoidal

 

 

 

1 = Triangular

 

 

 

2 = Square

 

 

 

NOTE: This parameter limits maximum weld current, see "OUTPUT LIMITATIONS" section of the manual.

 

 

6

Min. Weld Current Value with Remote Control,for TIG only.

10 Amps

 

(6 Amps - Value set for Indicator 7)

 

 

7

Max. Weld Current Value with Remote Control,for TIG only.

Peak Current

 

(Value set for Indicator 6 - Peak Current)

 

 

 

NOTE: Peak Current (Max Weld Current) can be limited by input voltage, welding mode, AC TIG waveform and AC TIG frequency.

 

 

8

Touch Start or H.F. Start in DC TIG (0 = H.F. Start, 1 = touch Start)

0

 

 

This parameter is ignored in AC TIG Mode

 

 

9

Reset all Parameters, (including control panel settings)

 

 

10

Not Used

 

 

11

Not Used

 

 

12

2 Step Trigger Selection

1

 

 

0 = Restart Disabled

 

 

 

1 = Restart Enabled

 

 

13

4 Step Trigger Selection

0

 

 

0 = Restart Disabled

 

 

 

1 = Restart Enabled

 

 

14

Start Power , for TIG only

2.0

 

 

This function sets the initial start energy limit.

 

 

 

(1.0 = min., 5.0 = max.)

 

 

 

Note: If the machine does not initiate a welding arc it will repeat the

 

 

 

starting sequence with an increased start energy up to this limit.

 

 

 

Set this number to a higher setting than the factory default if

 

 

 

needed to improve starting of large diameter tungstens electrodes.

 

 

 

 

 

 