A-1

TECHNICAL SPECIFICATIONS - V205-T AC/DC TIG K1855-1 (Code Number 10860)

INPUT - SINGLE PHASE ONLY

Input Voltages / 50 /60 Hz.

115

230

Max. Input Current

34A at Rated Output

30A at Rated Output

 

RATED OUTPUT

 

Duty Cycle

Output Amps

Volts at Rated Amperes

Input Amps

(115V) 35%

(Stick) 110

24.4V

34A

60%

90

23.6V

28A

100%

70

22.8V

20A

 

 

 

 

(115V) 40%

(TIG) 150

16V

34A

60%

120

14.8V

25A

100%

100

14V

20A

 

 

 

 

(230V) 35%

(Stick) 180

27.2V

30A

60%

150

26V

23A

100%

130

25.2V

19A

 

 

 

 

(230V) 40%

(TIG) 200

18V

30A

60%

170

16V

18A

100%

140

15.6V

15A

 

 

 

 

 

 

 

 

Output Current

Range

6-200 Amps

OUTPUT

Maximum Open

Circuit Voltage

54 Volts Max.

Type of Output

AC/DC

RECOMMENDED INPUT WIRE AND FUSE SIZES FOR MAXIMUM RATED OUTPUT

 

INPUT

TYPE S, SO ST, STO, OR EXTRA

TIME-DELAY CIRCUIT BREAKER

 

VOLTAGE /

HARD USAGE INPUT CORD AWG

OR FUSE SIZE (AMPS)

 

FREQUENCY

 

 

 

 

 

(HZ)

 

 

 

 

 

 

 

 

 

 

 

115/50/60

#12

 

30A

 

230/50/60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

Height

 

Width

 

Depth

 

Weight

15 in.

 

8.5 in.

 

19 in.

 

Approx. 38 lbs.

381 mm

 

216 mm

 

483 mm

 

17 kgs.

 

 

 

 

 

 

 

TEMPERATURE RANGES

OPERATING TEMPERATURE RANGE

-20°C to +40°C

STORAGE TEMPERATURE RANGE

-50°C to +85°C

V205-T AC/DC TIG