Lincoln Electric V300-PRO manual Next Step Test

Models: V300-PRO

1 40
Download 40 pages 30.09 Kb
Page 19
Image 19

 

 

 

 

 

 

Next

 

 

Step

 

 

Test

 

Test

 

 

Test

Check

Result

Conclusion

Step

Repair Action

 

 

 

 

 

 

 

 

7

D13 Input

9 (pos) to H1 (neg)

>1K ohms

OK

cont

 

 

 

Rectifier

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (pos) to A (neg)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

9 (pos) to H5 (neg)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (neg) to H1 (pos)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (neg) to A (pos)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (neg) to H5 (pos)

>1K ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

<100 ohms

Shorted

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (neg) to H1 (pos)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (neg) to A (pos)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

9 (neg) to H5 (pos)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (pos) to H1 (neg)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 (pos) to A (neg)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

12 ( pos) to H5 (neg)

<100 ohms

OK

cont

 

 

 

 

 

 

 

 

 

 

 

 

 

>1K ohms

Open

4-5

Replace D13, inspect S1,

 

 

 

 

 

 

 

test C1 and C2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19