Linear AE-2000 Power, Battery, & Ground Wiring, RS-232Port, Power Wiring, Earth Ground

Models: AE-2000

1 20
Download 20 pages 61.05 Kb
Page 11
Image 11
Power, Battery, & Ground Wiring

Power, Battery, & Ground Wiring

 

 

 

 

Power Wiring

 

 

 

 

 

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS

 

 

 

 

 

COMPLETE.TURN MASTER POWER SWITCH OFF BEFORE

 

 

 

 

 

WIRING.

POWER

 

 

1. Route two wires between the AE-2000 and the power transformer.

 

 

TERMINALS

 

• For power wire runs up to 75 feet, use 18 AWG, THHN 600-volt

 

DC

DC

AC2

AC1

EARTH

insulated wire.

 

 

 

 

 

• For power wire runs up to 150 feet, use 16 AWG, THHN 600-volt

 

 

 

 

GROUND

insulated wire.

 

 

 

 

 

 

 

 

STUD

2. Connect the wires to the transformer. Connect the other end of the

 

 

 

 

 

 

 

 

 

wires to the AE-2000 AC1 & AC2 terminals.

 

 

 

 

 

Backup Battery / Uninterruptable Power Supply

 

 

 

 

EARTH

Use of battery backup is optional. It will allow the AE-2000 to operate for

 

 

 

 

 

 

 

 

GROUND

short periods of time without AC power. The door or gate access device

 

 

 

 

 

 

 

 

STAKE

must use some type of battery backup of its own for the entire system to

12 VOLT

 

 

 

 

 

 

 

be functional.

BATTERY

 

 

 

 

A backup battery will not fi t into the AE-2000 case. Protect the backup

NOTE: THE OPTIONAL

 

 

 

 

battery inside a rain-tight NEMA enclosure suitable for the installation.

 

 

 

 

BACKUP BATTERY

 

 

 

 

NOTE: A backup battery is not required to maintain the AE-2000

 

 

 

 

WILL REQUIRE AN

 

 

 

 

clock/calendar and programming memory during power outages.

 

 

 

 

EXTERNAL CHARGER

 

 

 

 

1. Route two wires between the AE-2000 and the backup battery.

 

 

 

 

 

 

 

 

 

2. Connect the Battery positive to the AE-2000 DC+ terminal and the

 

 

 

 

16 VAC

negative to the DC- terminal.

 

 

 

 

 

 

 

 

50 VA

NOTE: The AE-2000 does not supply battery charging current.

 

 

 

 

TRANSFORMER

An external battery charger will be required to maintain the battery.

 

 

 

 

 

Earth Ground

 

 

 

 

 

For the best ground, use size 12 gauge solid wire or larger to connect to

 

 

 

 

 

an 8-foot copper ground rod. Locate the ground rod next to the Power and

 

 

 

 

 

Telephone company rods and bond the rods together with a new clamp.

 

 

 

 

 

Do not disturb the clamps installed by the Power or Telephone Company.

 

 

 

 

 

Alternately, connect to a metallic cold water pipe for the earth ground.

 

 

 

 

 

1. Connect the wire from the earth ground to the AE-2000’s EARTH

 

 

 

 

 

GROUND STUD.

 

 

 

 

 

RS-232 Port

 

 

 

 

 

A modular connector is provided for the bi-directional 38.4K baud RS-232

 

 

 

 

 

port.The AE-2000’s RS-232 port connects to a personal computer’s COM

AE-2000

 

 

 

 

port. System programming can be performed locally with a computer

RS-232 PORT

 

 

 

 

connected to the RS-232 port using the AccessBase 2000 software.

 

 

 

 

 

COMPUTER'S

COM PORT

SET COMPUTER COM PORT

LINEAR MODEL A2C BAUD RATE TO 38,400 BPS

SERIAL COMPUTER CABLE

NOTE: USE A DB-25 TO DB-9 CABLE ADAPTER IF REQUIRED

11