PBUS Accessories

PBUS Accessories

Six accessories (keypads, proximity readers, remote receivers) can be connected to the AE-2000’s three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate.

Linear’s PBUS devices compatible with the AE-2000 are:

AM-RRR Remote Radio Receiver

AM-RPR Radio Proximity Receiver

AM-KP Exterior Keypad

AM-KPI Interior Keypad

AM-CRI Card Reader Interface

1. Mount and install the accessory as described in its installation

instructions.

NOTE: UP TO SIX PBUS DEVICES MAY BE CONNECTED TO THE THREE SETS OF AE-2000

PBUS TERMINALS

PWR REMOTE DAT1 DEVICE

GND PBUSWiegand Accessories

REMOTE DAT1 WIEGANDManual background

PBUS

DAT0

DEVICE

DVAL Manual backgroundManual background

PCLK Manual backgroundManual background

PBUS

TERMINALS

PWR

GND

DAT1

DAT0

DVAL

PCLK

2. Route 6-conductor cable from the AE-2000 to the accessory.

For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.

For wire runs up to 600 feet use 20 AWG Weico Type 9405 or equivalent.

3.Set the DEVICE ADDRESS rotary switch in the accessory to a unique address number. When programming the system, the device address number will identify each PBUS accessory to the AE-2000.

4.Connect the 6-conductor cable to the accessory and the AE-2000.

SET THE REMOTE DEVICE ADDRESS SWITCH TO A UNIQUE DEVICE ADDRESS

Wiegand Accessories

The two AE-2000 Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.

NOTE: Depending on the Wiegand accessory used, the LED1, LED2, and HOLD connections may not be required.

LED1 output is switched to ground during non-access time.

LED2 output is switched to ground for one second during access

time.

1.Mount and install the Wiegand accessory as described in its installation instructions.

2.Route a cable from the AE-2000 to the accessory.

For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.

For wire runs up to 500 feet use 20 AWG Weico Type 9405 or equivalent.

LED2 Manual backgroundManual background

HOLD Manual backgroundManual background REMOTE LED1 Manual backgroundManual background WIEGAND DAT1 Manual backgroundManual background DEVICE DAT0 Manual backgroundManual background GND Manual backgroundManual background PWR Manual backgroundManual background

WIEGAND

TERMINALS

LED2

HOLD

LED1

DAT1

DAT0

GND

PWR

3.Connect the cable to the accessory and the AE-2000 as shown in the fi gure.

NOTE: THE LED1, LED2, AND HOLD CONNECTIONS MAY NOT BE REQUIRED DEPENDING ON THE WIEGAND DEVICE USED