Entry System Mounting (Continued)

Entry System Mounting (Continued)

Recessed Mounting

The cabinet can be mounted recessed using the accessory trim-ring (P/N ACP00914). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring.

1.Identify the location of any studs in the wall.

2.Cut a 15-½” wide by 19” high rectangular hole between studs at the mounting location.

3.Install any additional mounting material required to provide surfaces inside the wall 15-½” apart for attaching the trim-ring.

4.Place the trim-ring in the wall hole. Check for level, then attach the trim-ring with up to six screws into the side tabs.

5.Drill the cabinet’s six self-drill mounting holes the appropriate size for the hardware.

6.Attach the cabinet to the trim-ring using self-tapping screws.

7.After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.

1 DETERMINE LOCATION FOR

2 MARK HOLE LOCATION

THE 15-½" x 19" MOUNTING HOLE

 

 

RECESSED

 

MOUNTING

19"

 

15-½"

 

3 CUT MOUNTING HOLE

4 INSTALL ANY SHIMS TO

 

ALLOW MOUNTING AND

 

ATTACH THE TRIM-RING

 

WITH UP TO 6 SCREWS

DRILL 3/16" HOLES IN

5THE CABINET AT THE

PRE-MARKED LOCATIONS

ATTACH THE CABINET TO

6THE TRIM-RING WITH SELF-TAPING SCREWS

Pedestal Mounting

The cabinet can be mounted on a gooseneck pedestal. Linear manufacturers two pedestals: Model GNC-1 is for surface mounting with concrete fasteners, Model GNB-1 is for burial mounting. When mounting to a pedestal, use the cabinet reinforcing plate to stiffen the cabinet.

1.Install the pedestal at the desired location.

2.Place the reinforcing plate inside the cabinet.

3.Use security hardware to attach the cabinet and reinforcing plate to the pedestal.

4.After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire

ALIGN THE REINFORCING PLATE

ON THE INSIDE OF THE CABINET

PEDESTAL

MOUNTING

PEDESTAL

USE SECURITY HARDWARE

TO ATTACH THE PLATE AND

CABINET TO THE PEDESTAL