Wireless Transmitter Programming

Up to 500 wireless transmitters can be used with the system. Transmitters can be ordered in pre-programmed blocks of sequential ID codes. Up to 16 blocks of transmitters can be used. Transmitter blocks can be ordered with a Facility Code of 1-15 for block identifi cation if desired. Using Facility Codes is optional. For security, an individual transmitter can be deactivated in case it is lost or stolen.

NOTE: Transmitters will activate Relay Channels “A” or “B” depending on the setting of the transmitter button options. See the table below for the factory preset button options.Your installer may have modifi ed these options. Check boxes are provided to log any modifi ed button options.

TRANSMITTER BUTTON OPTIONS

SINGLE BUTTON,

RIGHT BUTTON

TOP BUTTON

 

BOTTOM RIGHT

TYPE OF

LEFT BUTTON,

(AVAILABLE ON SOME

BOTTOM LEFT BUTTON

OR TOP RIGHT BUTTON

BUTTON

TRANSMITTER

OR TOP LEFT BUTTON

MODELS ONLY)

 

 

 

 

 

 

N/A

N/A

N/A

N/A

SINGLE BUTTON

 

 

 

 

 

 

 

 

 

N/A

N/A

TWO BUTTON

 

 

 

 

 

 

NO RELAY

NO RELAY

NO RELAY (PRESET)

NO RELAY (PRESET)

NO RELAY (PRESET)

 

RELAY “A” (PRESET)

RELAY “A”

RELAY “A”

RELAY “A”

RELAY “A”

FOUR BUTTON

RELAY “B

RELAY “B” (PRESET)

RELAY “B”

RELAY “B”

RELAY “B”

 

RELAYS “A” & “B”

RELAYS “A” & “B”

RELAYS “A” & “B”

RELAYS “A” & “B”

RELAYS “A” & “B”

 

 

 

 

 

 

 

Assign Block Transmitter

Assigning a transmitter block assigns memory space for each block of transmitters used with the AE-500.

NOTE: When a block of transmitters is assigned, all transmitters in the block will become active and ready to use.

1.If not already in Programming Mode, connect by telephone or use the local keypad. Enter the master password and access programming.

2.Press

3. Enter the number of transmitters in the block.

4.Press

5.Enter the transmitter block’s facility code.

NOTE: Facility codes are optional. Enter 0 to have the system ignore the transmitter block’s facility code.

6.Press

7.Enter the fi rst (lowest) transmitter ID number for the block of transmitters.

8.Press

9.Exit Programming Mode if all programming is complete.

ASSIGN BLOCK TRANSMITTER

PPN 41

41#NUMBER#FC#ID#

NUMBER = NUMBER OF TRANSMITTERS IN THE BLOCK FC = FACILITY CODE 0-15 (0 IF UNUSED)

ID = LOWEST TRANSMITTER ID NUMBER IN THE BLOCK

Assign Single Enrolled Transmitter

Assigning a transmitter allocates memory space for the transmitter

NOTE: When a transmitter is assigned, it will become active and ready to use.

1.If not already in Programming Mode, connect by telephone or use the local keypad. Enter the master password and access programming.

2.Press

3. Enter the transmitter facility code (enter 0 if not used).

4.Press

5.Enter the transmitter ID number of the transmitter.

6.Press

7.Exit Programming Mode if all programming is complete.

ASSIGN SINGLE ENROLLED TRANSMITTER

PPN 45

45#FC#ID#

FC = FACILITY CODE (0 IF UNUSED)

ID = TRANSMITTER ID NUMBER

Suspend a Transmitter

Transmitters may be suspended if necessary (such as when a transmitter is lost or stolen).

1.If not already in Programming Mode, connect by telephone or use the local keypad. Enter the master password and access programming.

2.Press

3. Enter the transmitter’s facility code (enter 0 if not used).

4.Press

5.Enter the transmitter’s ID number.

6.Press

7.Exit Programming Mode if all programming is complete.

SUSPEND A TRANSMITTER

PPN 43

43#FC#ID#

FC = FACILITY CODE 0-15 (0 IF UNUSED) ID = TRANSMITTER ID NUMBER