Power, Battery, & Ground Wiring
Power Wiring
✦NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS COMPLETE.TURN MASTER POWER SWITCH OFF BEFORE WIRING.
1.Route two wires between the AE1000Plus and the power transformer.
•For power wire runs up to 100 feet, use 18 AWG, THHN
•For power wire runs up to 200 feet, use 16 AWG, THHN
2.Connect the wires to the transformer. Connect the other end of the wires to the AE1000Plus AC1 & AC2 terminals.
Backup Battery / Uninterruptable Power Supply
Use of battery backup is optional. It will allow the AE1000Plus to operate for short periods of time without AC power. The door or gate access device must use some type of battery backup of its own for the entire system to be functional.
A backup battery will not fi t into the AE1000Plus case. Protect the backup battery inside a
✦NOTE: A backup battery is not required to maintain the AE1000Plus clock/calendar and programming memory during power outages.
1.Route two wires between the AE1000Plus and the backup battery.
2.Connect the Battery positive to the AE1000Plus DC+ terminal and the negative to the DC- terminal.
✦NOTE: The AE1000Plus does not supply battery charging current. An external battery charger will be required to maintain the battery.
Earth Ground
POWER |
|
| ||
TERMINALS |
| |||
DC | DC | AC2 | AC1 | EARTH |
|
|
|
| GROUND |
|
|
|
| STUD |
|
|
|
| EARTH |
|
|
|
| GROUND |
12 VOLT |
|
|
| STAKE |
|
|
|
| |
BATTERY |
|
|
|
|
NOTE: THE OPTIONAL |
|
|
|
|
BACKUP BATTERY |
|
|
|
|
WILL REQUIRE AN |
|
|
|
|
EXTERNAL CHARGER |
|
|
|
|
|
|
|
| 16 VAC |
|
|
|
| 35 VA |
|
|
|
| TRANSFORMER |
For the best ground, use size 12 gauge solid wire or larger to connect the to an
1.Connect the wire from the earth ground to the AE1000Plus
EARTH GROUND STUD.
RS-232 Port
A modular connector is provided for the
AE1000PLUS
COMPUTER'S
COM PORT
SET COMPUTER COM PORT
LINEAR MODEL A2C BAUD RATE TO 38,400 BPS SERIAL COMPUTER CABLE
NOTE: USE A