Power, Battery, & Ground Wiring

Power, Battery, & Ground Wiring

Power Wiring

NOTE: DO NOT APPLY POWER UNTIL THE INSTALLATION IS COMPLETE.TURN MASTER POWER SWITCH OFF BEFORE WIRING.

1.Route two wires between the AE1000Plus and the power transformer.

For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire.

For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt insulated wire.

2.Connect the wires to the transformer. Connect the other end of the wires to the AE1000Plus AC1 & AC2 terminals.

Backup Battery / Uninterruptable Power Supply

Use of battery backup is optional. It will allow the AE1000Plus to operate for short periods of time without AC power. The door or gate access device must use some type of battery backup of its own for the entire system to be functional.

A backup battery will not fi t into the AE1000Plus case. Protect the backup battery inside a rain-tight NEMA enclosure suitable for the installation.

NOTE: A backup battery is not required to maintain the AE1000Plus clock/calendar and programming memory during power outages.

1.Route two wires between the AE1000Plus and the backup battery.

2.Connect the Battery positive to the AE1000Plus DC+ terminal and the negative to the DC- terminal.

NOTE: The AE1000Plus does not supply battery charging current. An external battery charger will be required to maintain the battery.

Earth Ground

POWER

 

 

TERMINALS

 

DC

DC

AC2

AC1

EARTH

 

 

 

 

GROUND

 

 

 

 

STUD

 

 

 

 

EARTH

 

 

 

 

GROUND

12 VOLT

 

 

 

STAKE

 

 

 

 

BATTERY

 

 

 

 

NOTE: THE OPTIONAL

 

 

 

 

BACKUP BATTERY

 

 

 

 

WILL REQUIRE AN

 

 

 

 

EXTERNAL CHARGER

 

 

 

 

 

 

 

 

16 VAC

 

 

 

 

35 VA

 

 

 

 

TRANSFORMER

For the best ground, use size 12 gauge solid wire or larger to connect the to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a metallic cold water pipe for the earth ground.

1.Connect the wire from the earth ground to the AE1000Plus

EARTH GROUND STUD.

RS-232 Port

A modular connector is provided for the bi-directional 38.4K baud RS-232 port. The AE1000Plus’s RS-232 port connects to a personal computer’s COM port. System programming can be performed locally with a computer connected to the RS-232 port.

AE1000PLUS

RS-232 PORT

COMPUTER'S

COM PORT

SET COMPUTER COM PORT

LINEAR MODEL A2C BAUD RATE TO 38,400 BPS SERIAL COMPUTER CABLE

NOTE: USE A DB-25 TO DB-9 CABLE ADAPTER IF REQUIRED