Entry System Mounting

The AE1000Plus cabinet is designed to be mounted three ways:

The unit can be mounted directly to a wall or fl at surface.

The unit can be mounted recessed into the wall.

The unit can be mounted on a standard gooseneck pedestal. Choose a well lit location near the controlled opening. Wiring access for power, telephone, earth ground, control output must be available to the mounting location. If the optional remote accessories are used, wiring access for these cables must also be available to the mounting location.

Mounting Preparation

Before mounting the system, the main circuit board mounting plate must be removed to provide access for the wiring hole and mounting fasteners.

CAUTION!: Touch a grounded object before proceeding to discharge static electricity from your body.

1GROUND WIRE STUD

CAREFULLY REMOVE THE FOUR WIRING HARNESS CONNECTORS & GROUND WIRE

MOUNTING

PREPARATION

2

LOOSEN THE TOP TWO NUTS & REMOVE THE BOTTOM TWO NUTS

1.Carefully remove the four main circuit board wiring connectors:

• The CPU/interface ribbon cable connector.

• The processor module power connector.

• The telephone interface connector.

• The tamper switch connector.

2.Remove the nut from the Earth Ground stud and remove the green ground wire lug from the stud.

3.Remove the two bottom circuit board mounting plate nuts.

4.Loosen the two top circuit board mounting plate nuts.

5.Carefully lift up on the mounting plate, removing the circuit board mounting plate. Set it aside in a safe place.

Reverse these steps to replace the circuit board mounting plate after the cabinet mounting is complete.

3CAREFULLY REMOVE THE CIRCUIT BOARD

Surface Mounting

The cabinet can be mounted on a wall or any suitable fl at surface. The four 3/8” mounting holes or the four self-drill locations can be used to attach the cabinet to the surface.

1.For wall mounting, hold the cabinet at the approximate mounting location where the display will be about eye level or slightly above.

2A. If using the 3/8” mounting holes, mark the four mounting hole centers. Drill as required. Use the appropriate fasteners for the mounting surface to secure the cabinet.

2B. If using the self-drill mounting holes, choose the correct size bit for the fasteners and drill the cabinet as required. Use the appropriate fasteners for the mounting surface to secure the cabinet.

3.After routing the wiring into the cabinet, replace the circuit board mounting plate and plug in the wiring connectors. Be sure to replace the green ground wire.

SURFACE

MOUNTING

OR

1 MARK THE FOUR MOUNTING HOLES

DRILL THE CABINET AT THE

PRE-MARKED LOCATIONS

2

ATTACH THE CABINET WITH APPROPRIATE

 

HARDWARE FOR THE MOUNTING SURFACE

8

Page 8
Image 8
Linear AE1000Plus installation instructions Entry System Mounting, Mounting Preparation, Surface Mounting

AE1000Plus specifications

The Linear AE1000Plus is a sophisticated access control and security system designed to meet the unique needs of residential and commercial environments. This advanced model is part of Linear’s commitment to providing reliable and efficient security solutions. It offers enhanced features, cutting-edge technologies, and exceptional characteristics that set it apart in the market.

One of the standout features of the AE1000Plus is its versatility in handling various access control modes. It supports access via key fobs, keypads, and biometric scanners, allowing for seamless integration with existing systems. This flexibility ensures that users can select the most appropriate method for their security requirements, enhancing convenience without compromising safety.

The AE1000Plus incorporates advanced wireless technology that facilitates easier installation and use. This wireless capability eliminates the need for extensive wiring, significantly reducing installation time and costs. Additionally, the system can communicate with Linear's extensive range of peripherals, including security cameras and alarm systems, providing a comprehensive security solution.

Another notable characteristic is its robust capacity for managing multiple users. The AE1000Plus can store a substantial number of user codes and fobs, making it ideal for larger facilities or properties with frequent visitor access. This feature empowers administrators with control over who can access specific areas while maintaining an audit trail of entries and exits.

The system is built with a user-friendly interface, ensuring ease of operation for both administrators and users. Programming and configuration can be streamlined through intuitive menus, while easily accessible manuals provide guidance for troubleshooting and adjustments. User experience is further enhanced by the AE1000Plus's compatibility with mobile applications, able to manage access remotely.

Security is paramount, and the AE1000Plus excels in implementing high-security standards. It employs encryption protocols that protect transmitted data from unauthorized access, ensuring the integrity and confidentiality of user information. The system is also designed to perform reliably in various environmental conditions, making it suitable for outdoor applications.

In summary, the Linear AE1000Plus combines versatility, advanced technology, and user-oriented design to create a leading access control solution. Its array of features ensures robust security while offering the flexibility to meet the demands of various settings, confirming Linear's position as a trusted name in the security industry. Whether for residential or commercial use, the AE1000Plus stands out as a reliable choice for modern security needs.