PBUS Accessories
Up to six accessories (keypads, proximity readers, remote receivers) can be connected to the three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate.
Linear’s PBUS devices compatible with the AE1000Plus are:
•
•
•
•
•
•
Conventional cable or commonly available
Cable choices:
•
•24 AWG Belden Type 9931 or equivalent for wire runs up to 300'.
•20 AWG Weico Type 9405 or equivalent for wire runs up to 600'.
1.Mount and install the accessory as described in its instructions.
2.Route cable from the AE1000Plus to the accessory.
3.Set the DEVICE ADDRESS rotary switch in the accessory to a unique address number. When programming the system, the device address number will identify each PBUS accessory to the AE1000Plus.
4.Connect the cable to the accessory and the AE1000Plus (see PBUS wiring diagram).
|
| PWR |
| PWR |
|
|
REMOTE | GND |
| GND |
|
| |
DAT1 |
| DAT1 | PBUS | |||
| PBUS |
| ||||
| DAT0 |
| DAT0 | TERMINALS | ||
| DEVICE |
| ||||
| DVAL |
| DVAL |
|
| |
|
|
|
|
| ||
|
| PCLK |
| PCLK |
|
|
| NOTE: UP TO SIX PBUS DEVICES MAY BE CONNECTED |
| ||||
| TO THE THREE SETS OF PBUS TERMINALS |
|
| |||
| ORANGE & |
| ORANGE & |
| ||
|
|
| ||||
BROWN & |
|
|
|
| BROWN & | |
|
|
| ||||
PWR |
|
|
|
|
| PWR |
GND |
| GND | ||||
DAT1 |
| DAT1 | ||||
GREEN |
|
|
| GREEN | ||
DAT0 |
|
|
| DAT0 | ||
|
|
|
|
| ||
DVAL | BLUE |
|
|
| BLUE | DVAL |
PCLK |
|
| PCLK | |||
|
|
|
| |||
REMOTE PBUS |
|
| ACCESS | |||
DEVICE TERMINALS | CONTROL SYSTEM | |||||
|
|
| PBUS TERMINALS | |||
|
|
| ||||
|
|
|
|
|
| |
|
|
| UP TO 500 FEET PER DEVICE |
|
|
|
Wiegand Accessories
The two AE1000Plus Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and
✦NOTE: Depending on the Wiegand accessory used, the LED1, LED2, and HOLD connections may not be required.
•LED1 output is switched to ground during
•LED2 output is switched to ground for one second during access time.
1.Mount and install the Wiegand accessory as described in its installation instructions.
2.Route a cable from the AE1000Plus to the accessory.
•For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.
•For wire runs up to 500 feet use 20 AWG Weico Type 9405 or equivalent.
LED2
HOLD REMOTE LED1 WIEGAND DAT1 DEVICE DAT0 GND PWR
WIEGAND
TERMINALS
LED2
HOLD
LED1
DAT1
DAT0
GND
PWR
3.Connect the cable to the accessory and the AE1000Plus as shown in the fi gure.
NOTE: THE LED1, LED2, AND HOLD CONNECTIONS MAY NOT BE REQUIRED DEPENDING ON THE WIEGAND DEVICE USED
14