Up to six accessories (keypads, proximity readers, remote receivers) can be connected to the three PBUS input/output ports. A typical application for a remote keypad would be to control a second door or gate.

Linear’s PBUS devices compatible with the AE1000Plus are:

AM-RRR Remote Radio Receiver

AM-RGR Remote Radio Receiver

AM-RPR Radio Proximity Receiver

AM-KP Exterior Keypad

AM-KPI Interior Keypad

AM-CRI Card Reader Interface

Conventional cable or commonly available Cat-5e Ethernet cable can be used to connect PBUS remote devices to the AE1000Plus. When using Cat-5e cable, note that the PWR and GND connections use two wires each to enhance the current carrying capacity for powering the remote device.

Cable choices:

Cat-5e Ethernet cable for wire runs up to 500'.

24 AWG Belden Type 9931 or equivalent for wire runs up to 300'.

20 AWG Weico Type 9405 or equivalent for wire runs up to 600'.

1.Mount and install the accessory as described in its instructions.

2.Route cable from the AE1000Plus to the accessory.

3.Set the DEVICE ADDRESS rotary switch in the accessory to a unique address number. When programming the system, the device address number will identify each PBUS accessory to the AE1000Plus.

4.Connect the cable to the accessory and the AE1000Plus (see PBUS wiring diagram).

 

 

PWR

 

PWR

 

 

REMOTE

GND

 

GND

 

 

DAT1

 

DAT1

PBUS

 

PBUS

 

 

DAT0

 

DAT0

TERMINALS

 

DEVICE

 

 

DVAL

 

DVAL

 

 

 

 

 

 

 

 

 

PCLK

 

PCLK

 

 

 

NOTE: UP TO SIX PBUS DEVICES MAY BE CONNECTED

 

 

TO THE THREE SETS OF PBUS TERMINALS

 

 

 

ORANGE &

 

CAT-5e WIRING EXAMPLE

ORANGE &

 

 

ORANGE-WHITE

 

ORANGE-WHITE

 

BROWN &

 

 

 

 

BROWN &

BROWN-WHITE

 

 

 

BROWN-WHITE

PWR

 

 

 

 

 

PWR

GND

GREEN-WHITE

 

GREEN-WHITE

GND

DAT1

 

DAT1

GREEN

 

 

 

GREEN

DAT0

 

 

 

DAT0

 

 

 

 

 

DVAL

BLUE

 

 

 

BLUE

DVAL

PCLK

BLUE-WHITE

 

 

BLUE-WHITE

PCLK

 

 

 

 

REMOTE PBUS

 

 

ACCESS

DEVICE TERMINALS

CAT-5e

CONTROL SYSTEM

 

 

 

PBUS TERMINALS

 

 

 

4-UTP CABLE

 

 

 

 

 

 

 

 

 

UP TO 500 FEET PER DEVICE

 

 

 

Wiegand Accessories

The two AE1000Plus Wiegand inputs (WIEGAND A & B) can connect to a large variety of 26, 30, and 31-bit Wiegand output accessories. The Wiegand format is a common standard for access control equipment. A typical application would be to add swipe card or proximity readers to the system.

NOTE: Depending on the Wiegand accessory used, the LED1, LED2, and HOLD connections may not be required.

LED1 output is switched to ground during non-access time.

LED2 output is switched to ground for one second during access time.

1.Mount and install the Wiegand accessory as described in its installation instructions.

2.Route a cable from the AE1000Plus to the accessory.

For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.

For wire runs up to 500 feet use 20 AWG Weico Type 9405 or equivalent.

LED2 Wiegand AccessoriesWIEGAND

HOLD Manual backgroundManual background REMOTE LED1 Manual backgroundManual background WIEGAND DAT1 Manual backgroundManual background DEVICE DAT0 Manual backgroundManual background GND Manual backgroundManual background PWR Manual backgroundManual background

WIEGAND

TERMINALS

LED2

HOLD

LED1

DAT1

DAT0

GND

PWR

3.Connect the cable to the accessory and the AE1000Plus as shown in the fi gure.

NOTE: THE LED1, LED2, AND HOLD CONNECTIONS MAY NOT BE REQUIRED DEPENDING ON THE WIEGAND DEVICE USED