4.7CONSOLE HOME-AUTOMATION OUTPUT

4.7CONSOLE HOME-AUTOMATION OUTPUT

PURPOSE:

For setting the way the home-automation output functions.

USER RESPONSE:

HOME AUTOMATION-OUTPUT

WHEN TRIGGERED: Select TOGGLES to cause the home-automation output to switch between on & off with each activation. Select ACTIVE FOR SET DURATION for a timed home-automation output and enter the length of time 1-2500 (in seconds) for the output to activate.

WHEN ACTIVE: Select OPEN to have the home-automation minus terminal fl oat when the output is active. Select SHORTED TO COMMON to have the home-automation minus terminal switch to common ground when the output is active.

AUDIBLE BELL WHEN TRIGGERED: With this box checked, the Console will sound a “bing” when the home-automation output is activated. Un-check this box to have the home-automation output activate silently.