Quick Start Guide: Options
Door Release
The VMC1 Security Intercom System supports up to three remote electronic door release mechanisms.
To activate a door release:
1.Press the Door Chime button at a Video Door Station. The RED Status LED blinks at all Stations indicating an active Page
2.Press and hold DOOR button at any interior Station to speak to the visitor.
3.Release to listen: Green Status LED lights at that station to indicate an active microphone.
4.Release the DOOR button and light goes off.
NOTE: No other Stations can communicate once the door is answered by another Station
5.The visitor responds hands free
6.Press LOCK button to activate electronic door release.
Door lock remains open for four (4) seconds, and then locks.
NOTE: Press LOCK again to reopen as long as the communication is active
Only the responding Station can activate the door release, preventing accidental door opening when pressing LOCK button
Home Automation
VMC1 Security Intercom System supports two
•Remotely turn on lights
•Trigger an alert on an alarm panel
•Activate environmental controls
With AUX Output Operations, homeowners can activate home automation functions using the following controls:
Single Digit
•Press AUX
•Followed by button 1 for AUX 1 or button 2 for AUX2.
Double Digit
•Press 7
•Followed by button 1 for AUX 1 or 2 for AUX 2
9