10 Diagrams (continued)

Figure 10-2Ladder Diagram

120VAC

JUNCTION BOX

NEUTRAL

TERMINAL STRIP

 

TERMINAL STRIP

120V SUPPLY "L"

 

120V SUPPLY "N"

 

 

L

 

 

IN

GROUND

ON / OFF

INTEGRATED CONTROL

 

 

 

SWITCH

 

 

 

BLOWER

 

X1-6

F2

 

X1-1

1

2

 

3.15A

 

 

 

 

 

F1

 

X1-2

3

 

 

 

 

 

 

5A

SYSTEM PUMP

SYSTEM PUMP

 

 

 

RELAY

X1-3

RELAY

 

 

 

DHW PUMP

 

DHW PUMP

 

 

 

RELAY

X1-4

RELAY

 

 

 

 

 

 

 

 

BOILER PUMP

 

BOILER PUMP

 

 

F3

RELAY

 

RELAY

 

 

.8A

24V DC

 

 

 

X5-9

 

SUPPLY

X5-1

 

 

 

 

 

120 VAC

 

 

 

 

 

3.5A

 

 

 

 

SYSTEM

PUMP

CONTACTS

BOILER

PUMP

CONTACTS

DHW

PUMP

CONTACTS

RELAY BOARD

L

OUT

SYSTEM

PUMP

BOILER

PUMP

DHW

PUMP

X4-3

KB 801

ONLY

CN5-5

PC INTERFACE

ALARM BELL

1

24 VAC

 

 

CONNECTION BOARD

 

 

 

 

 

 

 

 

 

 

 

 

 

INTEGRATED

 

LWCO

 

 

 

 

 

 

CONTROL

 

 

 

FLOW

 

CN5-14

X4-8

 

 

 

 

 

 

 

 

 

 

 

CN7-3

 

CN7-4

11

SWITCH

12

 

 

 

 

 

CN5-10

X4-12

 

24 VAC

 

 

 

 

 

 

 

 

 

 

 

 

CN7-1

 

CN7-2

 

 

 

 

 

 

 

HEAT/LOOPDEMAND 1

 

 

 

CN5-7

X4-1

 

 

 

 

 

 

19

 

20

 

 

 

 

 

 

 

HEAT/LOOPDEMAND 2

 

 

 

CN5-13

X4-9

 

 

 

 

 

 

17

 

18

 

 

 

 

 

 

 

HEAT/LOOPDEMAND 3

 

 

 

CN5-6

X4-2

 

 

 

 

 

 

15

 

16

 

 

 

 

 

 

 

TANK

 

 

 

 

 

 

 

THERMOSTAT

 

 

 

CN5-12

X4-10

 

 

 

 

 

 

13

 

14

 

 

 

 

 

 

 

LOW GAS

HIGH GAS

 

 

 

 

 

 

 

PRESSURE

PRESSURE

 

 

 

 

 

 

 

SWITCH

SWITCH

 

 

 

CN5-11

X4-11

 

 

 

 

 

 

10

 

9

 

 

 

CN5-3

X4-5

 

 

INTEGRATED

 

 

 

 

 

 

LOUVER

 

 

 

 

 

 

CONTROL

 

5

 

 

 

 

 

 

 

RELAY COIL

 

 

 

 

 

 

 

 

24VAC

6

 

 

 

 

 

 

 

LOUVER

7

 

 

 

 

 

 

 

PROVING SWITCH

CN5-4

X4-4

 

 

 

 

 

 

 

 

 

 

 

 

 

X7

 

 

8

 

 

 

 

RIBBON CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5-2

 

 

 

 

O-TEMP HEX SW

BLOCKED

 

X5-10

 

 

X5-6

 

DRAIN SWITCH

 

S2

 

 

 

 

INLET

 

 

 

 

 

 

 

SENSOR

 

 

 

 

AIR PRESSURE

 

 

 

 

 

X5-4

 

 

 

X5-11

OPERATING S1a

 

 

SWITCH

 

SENSOR

 

 

 

 

 

 

 

 

HIGH LIMIT

S1b

X5-12

 

GAS VALVE

 

 

 

 

 

 

X2-2

SENSOR

 

 

 

 

 

 

2

6

FLUE SENSOR

S3a

X5-5

X5-13

 

GAS VALVE

X2-1

RELAY

FLUE

S3b

SENSOR

X5-14

13

CONNECTION

BOARD

BLOWER

1

X5-7

 

2

X5-16

 

ALARM

1

 

CN5-1

 

X4-7

 

 

 

 

 

 

 

CONTACTS

2

 

CN5-8

 

X4-14

 

 

 

 

 

 

 

 

 

 

 

 

3

 

CN5-2

 

X4-6

 

 

RUN-TIME

 

 

 

 

 

CONTACTS

4

 

CN5-9

 

X4-13

 

 

 

 

 

 

 

 

 

SYSTEM

S6

21

 

CN6

 

X6

 

 

 

 

 

 

SENSOR

 

22

 

CN6

 

X6

 

OUTDOOR

S5

23

 

CN6

 

X6

 

 

 

 

 

 

SENSOR

 

24

 

 

 

 

 

TANK

S4

26

 

CN6

 

X6

 

 

 

 

 

 

SENSOR

 

27

 

CN6

 

X6

 

SHIELD

 

29

 

CN6

 

 

 

 

A

 

30

 

 

X6

 

CASCADE

 

 

 

 

 

 

B

 

31

 

CN6

 

X6

 

 

 

 

 

 

 

 

SHIELD

 

32

 

CN6

 

X6

 

 

 

 

 

 

 

BMS +

 

33

 

CN6

 

X6

 

0-10V

 

 

 

 

 

IN -

34

 

CN6

 

X6

 

 

 

 

 

 

 

CN6

 

 

 

SYS PUMP

+

 

35

 

 

X6

 

0-10V

 

 

 

 

 

IN

-

36

 

CN6

 

X6

 

 

 

 

 

BLR PUMP

+

 

37

 

CN6

 

X6

 

0-10V

 

 

 

 

 

OUT

-

38

 

CN6

 

X6

 

 

 

 

 

RATE

+

 

39

 

CN6

 

X6

 

0-10V

 

 

 

 

 

OUT

-

40

 

 

 

 

 

 

 

 

M

 

 

SHIELD

 

41

 

 

 

 

 

A

 

42

CN8-1

X6-1

O

X4-1

X9-2

 

 

D

MODBUS B

 

43

CN8-2

X6-2

B

X4-2

X9-1

SHIELD

 

44

CN8-3

X6-3 U

X4-3

X9-3

 

 

 

S

 

 

 

 

 

 

 

 

 

 

4 X5-8

5 X5-15

TR2

X1-7

FLAME ROD

SPARK

ROD

CAUTION HIGH VOLTAGE SPARK LEAD

NOTES:

1.Where possible, switches are shown without utilities (gas, water or electricity) connected to the unit. As such, actual switch states may vary from those shown on diagrams depending upon whether utilities are connected or a fault condition is present.

2.See wiring diagram for additional notes.

BOX DEPICTS

OPTIONAL ITEMS

LOW VOLTAGE 120 VAC HIGH VOLTAGE

LADDER DIAGRAM

LBL20141 REV D