Outdoor Knight XL Installation & Operation Manual
10 Diagrams (continued)
Figure 10-2 Ladder Diagram
120VAC | JUNCTION BOX | NEUTRAL |
TERMINAL STRIP |
| TERMINAL STRIP |
120V SUPPLY "L" |
| 120V SUPPLY "N" |
|
| L |
|
| IN |
GROUND
ON / OFF | INTEGRATED CONTROL |
|
|
| |
SWITCH |
|
|
| BLOWER |
|
F2 |
| 1 | 2 | ||
| 3.15A |
|
|
|
|
| F1 |
| 3 |
| |
|
|
|
| ||
| 5A | SYSTEM PUMP | SYSTEM PUMP |
| |
|
| RELAY | RELAY |
| |
|
| DHW PUMP |
| DHW PUMP |
|
|
| RELAY | RELAY |
| |
|
|
|
|
| |
|
| BOILER PUMP |
| BOILER PUMP |
|
| F3 | RELAY |
| RELAY |
|
| .8A | 24V DC |
|
|
|
| SUPPLY |
| |||
|
|
| |||
| 120 VAC |
|
|
|
|
| 3.5A |
|
|
|
|
SYSTEM |
PUMP |
CONTACTS |
BOILER |
PUMP |
CONTACTS |
DHW |
PUMP |
CONTACTS |
RELAY BOARD |
L
OUT
SYSTEM
PUMP
BOILER
PUMP
DHW
PUMP
KB 801
ONLY
PC INTERFACE ![](/images/new-backgrounds/1054615/54615109xi2.webp)
ALARM BELL | 1 |
24 VAC
|
| CONNECTION BOARD |
|
|
|
|
| |
|
|
|
|
|
|
|
| INTEGRATED |
| LWCO |
|
|
|
|
|
| CONTROL |
|
|
| FLOW |
| ||||
|
|
|
|
| ||||
|
|
|
|
|
| |||
| 11 | SWITCH | 12 |
|
|
| ||
|
| |||||||
| 24 VAC |
|
|
|
| |||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ||
| HEAT/LOOPDEMAND 1 |
|
|
| ||||
|
|
|
|
|
| |||
19 |
| 20 |
|
|
|
|
|
|
| HEAT/LOOPDEMAND 2 |
|
|
| ||||
|
|
|
|
|
| |||
17 |
| 18 |
|
|
|
|
|
|
| HEAT/LOOPDEMAND 3 |
|
|
| ||||
|
|
|
|
|
| |||
15 |
| 16 |
|
|
|
|
|
|
| TANK |
|
|
|
|
|
| |
| THERMOSTAT |
|
|
| ||||
|
|
|
|
|
| |||
13 |
| 14 |
|
|
|
|
|
|
| LOW GAS | HIGH GAS |
|
|
|
|
|
|
| PRESSURE | PRESSURE |
|
|
|
|
|
|
| SWITCH | SWITCH |
|
|
| |||
|
|
|
|
|
| |||
10 |
| 9 |
|
|
| |||
|
| INTEGRATED |
|
|
| |||
|
|
| LOUVER |
|
|
|
| |
|
| CONTROL |
| 5 |
|
|
| |
|
|
|
| RELAY COIL |
|
|
|
|
|
|
|
| 24VAC | 6 |
|
|
|
|
|
|
| LOUVER | 7 |
|
|
|
|
|
|
| PROVING SWITCH | ||||
|
|
|
|
| ||||
|
|
|
|
|
| |||
|
| X7 |
|
| 8 |
|
|
|
| RIBBON CABLE |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
|
|
| BLOCKED |
| |||
|
|
| DRAIN SWITCH | |||||
| S2 |
|
|
|
| |||
INLET |
|
|
|
|
|
|
| |
SENSOR |
|
|
|
| AIR PRESSURE |
|
|
|
|
|
|
|
| ||||
OPERATING S1a |
|
| SWITCH |
| ||||
SENSOR |
|
|
|
|
|
|
|
|
HIGH LIMIT | S1b |
| GAS VALVE |
|
|
| ||
|
|
| ||||||
SENSOR |
|
|
|
|
|
|
2
6
FLUE SENSOR
S3a
| GAS VALVE |
RELAY |
FLUE
S3b
SENSOR
13
CONNECTION
BOARD
BLOWER | 1 | |
| 2 |
|
| ALARM | 1 |
|
|
| |||
|
|
|
|
|
| |||
CONTACTS | 2 |
|
|
| ||||
|
|
|
|
|
|
|
| |
|
|
| 3 |
|
|
| ||
|
|
|
|
|
| |||
CONTACTS | 4 |
|
|
|
| |||
|
|
|
|
|
|
|
| |
SYSTEM | S6 | 21 |
| CN6 |
| X6 |
| |
|
|
|
|
| ||||
SENSOR |
| 22 |
| CN6 |
| X6 |
| |
OUTDOOR | S5 | 23 |
| CN6 |
| X6 |
| |
|
|
|
|
| ||||
SENSOR |
| 24 |
|
|
|
|
| |
TANK | S4 | 26 |
| CN6 |
| X6 |
| |
|
|
|
|
| ||||
SENSOR |
| 27 |
| CN6 |
| X6 |
| |
SHIELD |
| 29 |
| CN6 |
|
|
| |
| A |
| 30 |
|
| X6 |
| |
CASCADE |
|
|
|
|
|
| ||
B |
| 31 |
| CN6 |
| X6 |
| |
|
|
|
|
|
|
| ||
SHIELD |
| 32 |
| CN6 |
| X6 |
| |
|
|
|
|
|
| |||
BMS + |
| 33 |
| CN6 |
| X6 |
| |
|
|
|
|
| ||||
IN - | 34 |
| CN6 |
| X6 |
| ||
|
|
|
| |||||
|
| CN6 |
|
|
| |||
SYS PUMP | + |
| 35 |
|
| X6 |
| |
|
|
|
|
| ||||
IN | - | 36 |
| CN6 |
| X6 |
| |
|
|
|
| |||||
BLR PUMP | + |
| 37 |
| CN6 |
| X6 |
|
|
|
|
|
| ||||
OUT | - | 38 |
| CN6 |
| X6 |
| |
|
|
|
| |||||
RATE | + |
| 39 |
| CN6 |
| X6 |
|
|
|
|
|
| ||||
OUT | - | 40 |
|
|
|
|
| |
|
|
| M |
|
| |||
SHIELD |
| 41 |
|
|
|
| ||
| A |
| 42 | O | ||||
|
| D | ||||||
MODBUS B |
| 43 | B | |||||
SHIELD |
| 44 | ||||||
|
|
| S |
|
| |||
|
|
|
|
|
|
|
|
4
5
TR2
FLAME ROD
SPARK
ROD
CAUTION HIGH VOLTAGE SPARK LEAD
NOTES:
1.Where possible, switches are shown without utilities (gas, water or electricity) connected to the unit. As such, actual switch states may vary from those shown on diagrams depending upon whether utilities are connected or a fault condition is present.
2.See wiring diagram for additional notes.
BOX DEPICTS
OPTIONAL ITEMS
LOW VOLTAGE 120 VAC HIGH VOLTAGE
LADDER DIAGRAM
LBL20141 REV D
55