Venting the Pellet Stove

Installation (For Qualified Installers Only)

9

Venting the Pellet Stove

PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER).

DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

USE AN APPROVED WALL THIMBLE WHEN PASSING THE VENT THROUGH WALLS AND A CEILING SUPPORT/FIRE STOP SPACER WHEN PASSING THE VENT THROUGH CEILINGS (MAKE SURE TO MAINTAIN 3" CLEARANCE TO ANY COMBUSTIBLES.

No more than one tee and 180° of elbows (one tee with two 90° elbows, one tee with one 90° and two 45° elbows, etc.).

Maximum Venting 33 Feet (max.)

Maximum Venting

Distance:

Vent must have a support bracket every 5' of pellet vent when exterior of structure

The vent height and run must not exceed the distance shown in the shaded region shown to the right.

Manual background 30 Feet

Manual background 25 Feet

Manual background 20 Feet

Venting into this shaded area may require restrictor adjustments. See the

Manual background 15 Feet

section “Restrictor Adjustment” for details.

Manual background 10 Feet

NOTE: To achieve optimum performance, we recommend keeping the vent as short as possible (horizontal run especially).

0 Feet

Manual background 5 Feet

 

 

 

 

 

0 Feet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10Feet (max.)

 

5Feet

 