Clean the Baffles

Maintenance2 9

Bi-Weekly Maintenance (or every 10 bags of pellets) - Continued

Clean the Baffles

Cleaning the Baffles

The baffles are located along the top of the firebox. Follow the directions below to remove the baffle and shake any flyash from baffle onto the firebox floor (NOTE: you do not need to remove the baffle from the firebox).

Left Side Baffle

Right Side Baffle Manual backgroundManual backgroundManual backgroundManual background

a

Remove the refractory following the

directions below.

 

Remove both refractory side clips.

Remove the firepot.

Lift the refractory up and forward to remove.

b

Left Side Baffle Manual background

Note how this tab inserts into this slot in the baffle.

The baffle rests on this ledge at the back of the firebox.

Heat Exchange Tubes

c

Lift the left side baffle up and move it towards the front of the stove. Rotate the back of the baffle forward.

d

With the baffle free of the ledge, bring it downwards and tap any flyash onto the floor of the firebox.

e

Repeat step “b” through “d” for the right side baffle.

To replace the baffles:

follow the above procedure in reverse.