Louisville Tin and Stove 90N30A For Your Safety Read Before Lighting, Lighting Instructions

Models: 90N50A 90N30A 90N65A 90N75A

1 19
Download 19 pages 12.75 Kb
Page 11
Image 11
FOR YOUR SAFETY READ BEFORE LIGHTING

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instruc- tions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire

department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

WHAT TO DO IF YOU SMELL GAS: LIGHTING INSTRUCTIONS LIGHTING INSTRUCTIONS

1.STOP! Read the information on the safety label.

2.Set thermostat to lowest setting.

3.Remove the floor grille.

4.Place the furnace key on the control rod, push down

slightly and turn clockwise Pilot to “ALL OFF”.

Pilot

Pilot is located

Burner

on the side of

 

and toward

 

control end

BURNER

Control

Rod

ALL OFF

NOTE: Control rod cannot be turned from “PILOT” to “ALL OFF” unless the control rod is pushed down slightly.

of burner

9. Locate the red piezo igniter button beside the control rod.

10. Press down on the control rod with the furnace key.

Immediately begin a series of pushing and releasing the

red piezo igniter while observing the pilot through the sight

glass opening, continue to spark until pilot is lit or use the

5.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B’ in the information on the safety label. If you don’t smell gas, go to the next step.

6.Remove the sight glass assembly from the opening on top of the heat exchanger.

7.Locate the pilot burner looking down through the sight glass opening.

8. Turn the control rod counterclockwise

until

the pointer is on “PILOT”.

 

lighter rod with match. Continue to hold the control rod

down for about one (1) minute after the pilot is lit. If it goes

out, repeat steps 4 through 10.

If control rod does not pop up when released, STOP and immediately call your service technician or gas supplier.

If the pilot will not stay lit after several tries, turn the control rod to “OFF” and call your service technician or gas supplier.

11.Replace the sight glass assembly and turn the control rod

counterclockwise Pilot is located to “BURNER” position. Remove furnace key and replace the floor grille.

12.Set thermostat to desired temperature.

BurnerTO TURN OFF GAS TO APPLIANCEon the side of

1.Set the thermostat to it’s lowest setting.

2.Allow floor grille to cool, then remove.

3.Place furnace key on control rod, push slightly and

turn clockwise and toward to “ALL OFF”. Do not force.

4.Replace floor grille.

Page 11