Louisville Tin and Stove 90N50A, 90N75A Contents, Introduction, Floor Furnace Specifications

Models: 90N50A 90N30A 90N65A 90N75A

1 19
Download 19 pages 12.75 Kb
Page 2
Image 2

CONTENTS:

Introduction

2

Specifications

2

Safety Rules

2

Helpful Installation Information

3

Installation Requirements

3

Furnace Location

4

Fresh Air for Combustion & Venting

4

Cutting the Floor Opening

5

Setting the Floor Furnace

5

Installing the Draft Hood

6

Connecting the Vent

6

Gas Supply and Piping

8

Checking the Gas Piping

9

Thermostat Installation

10

Lighting

11

To Turn Off Gas

11

Adjusting the Pilot Flame

12

Orifice Charts

12

Adjusting the Main Burner

12

Optional Operation

13

Maintenance

14

Trouble Shooting

15

Repair Parts

16

Warranty

18

INTRODUCTION

THIS IS A GAS-FIRED, GRAVITY VENTED FLOOR FURNACE THAT WILL OPERATE SAFELY AND PROVIDE AN EFFICIENT SOURCE OF HEAT WHEN INSTALLED, OPERATED AND MAINTAINED AS RECOMMENDED IN THESE INSTALLATION AND OPERATING INSTRUCTIONS. READ THESE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING, SERVICING, OR USING THE APPLIANCE. IF YOU DO NOT UNDERSTAND ANY PART OF THESE INSTRUCTIONS, CONSULT LOCAL AUTHORITIES, OTHER QUALIFIED INSTALLERS, SERVICE AGENCIES, THE GAS SUPPLIER OR THE MANUFACTURER.

FLOOR FURNACE SPECIFICATIONS

Your floor furnace and drafthood are packed together in one master carton. The carton containing the floor furnace also contains the thermostat, thermostat wire, insulated staples, furnace key and lighter rod. The drafthood is packed in its own carton within the master pack and contains screws and rope-like gasket material for attaching and sealing the draft hood to the floor furnace. Check the model numbers on the two cartons to be sure they match.

MODEL NUMBER – NAT. GAS

90N30A

90N50A

90N65A

90N75A

Hourly BTU Input

30,000

50,000

62,000

75,000

Width and Length

14”x32”

22”x32”

24”x38”

26”x42”

Overall Height

29-1/4”

29-1/4”

29-7/8”

30-7/8”

Overall Grille Size

16”x34-c

24”x34”

26”x40”

28”x44”

Size of Floor Opening

143”x323

222”x322

242”x382

262”x422

Gas Pipe Size at Furnace

½”

½”

½”

½”

Vent Pipe Size

4”

4”

5”

5”

Floor to Center Line of Vent

22”

22”

22”

22”

SAFETY RULES

1.WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR THE GAS SUPPLIER. KEEP BURNER AND CONTROL COMPARTMENT CLEAN. SEE INSTALLATION AND OPERATING INSTRUCTIONS ACCOMPANYING APPLIANCE. DUE TO HIGH SURFACE TEMPERATURES KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.

Page 2

Page 2
Image 2
Louisville Tin and Stove 90N50A, 90N75A, 90N65A, 90N30A Contents, Introduction, Floor Furnace Specifications, Safety Rules