CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WIRING INSTRUCTIONS –
GRAVITYWALLFURNACE
WARNING: Failure to locate the thermostat properly or to wire the furnace correctly may result in continuous operation, control damage or failure to operate. This can cause property damage, personal injury, or loss of life.
Follow the instructions included with the thermostat. Locate the thermostat approximately five (5) feet above the floor and four feet (4’) from appliance. Always mount the thermostat on an inside wall where it won’t be affected by heat or cold sources such as direct sunlight, televisions, fireplaces, hidden hot or cold water pipes, drafts, etc. The thermostatmustneverbeinstalledinanadjoiningroomwhere a door can be closed between the thermostat and wall furnace. This wall furnace is equipped with a self generating control system. Never connect to a 24 volt transformer or to the household electrical system. Do not use more thermostat wire than is included with the wall furnace. Do not run thermostat wire in same stud space with vent. Conceal wire inside wall or secure to wall with insulated staples that are included .
YOUR FURNACE IS SHIPPED WITH A WALL THERMOSTAT (Figure 8). YOU MAY CONVERT CONTROL TO
FOR INSTALLATION INSTRUCTIONS.
Thermostat
|
| Manual |
|
|
|
| Reset |
|
|
|
| Blocked |
| Pilot |
|
| Flue Switch | ||
|
| Generator | ||
|
|
|
| |
WALL | Wire |
| ||
THERMOSTAT | Nut |
| ||
MODELS |
|
|
| |
NAT. | L.P. |
|
| |
W255F | W256F |
|
| |
W355F | W356F |
| Gas Valve | |
W505F | W506F |
|
FIGURE8
Page 10