PILOT ADJUSTMENT

PILOT ADJUSTMENT

Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or thermocouple (see below). The pilot is unregulated so it will be operating at inlet line pressure (Max. 7” w.c. for natural gas and 11” w.c. for propane). To decrease the pilot flame, turn the screw clockwise (approximately seven to nine full turns to bottom of pilot light channel) until you produce sufficient flame at the minimum noise level.

PILOT FLAME ADJUSTMENT

3/8 TO 1/2 INCH

PILOT FLAME SHOULD ENVELOP 3/8 TO 1/2 INCH

OF THE TIP OF THE GENERATOR.

MAINTENANCE INSTRUCTIONS

1.Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, pilot burners, circulating air passageways and venting systems of the appliance be kept clean.

2.If the appliance has been equipped with the optional WFF81-C fan kit assembly, the bearings of the motor should be oiled every six months with approximately 2 drops of S.A.E. 20 oil.

3.The appliance area must be kept clear and free of any combustible materials, gasoline and other flammable vapors and liquids.

4.It is essential that the flow of combustion and ventilation air not be obstructed.

5.Periodic examination of the entire ventilation system as a routine part of the safety performance check is recommended on an annual basis.

BURNER FLAME ADJUSTMENT - STAINLESS STEEL BURNER

123

Air

Shutter

1.FLAMETOO SOFT -Yellow Flame. Open air shutters until yellow tipping disappears.

2. FLAME TOO HARD - Deep Blue

3. NORMALFLAMES

Coloration. Closing air shutters

 

to a point where yellow tipping

 

begins, re-open slightly to

 

eliminate yellow tipping. Air

 

shutter adjustment is now correct.

 

NOTE: It is advised that the burner flames be checked at least twice during the heating season for any changes in burner characteristics. Vacuum burner compartment at start of heating season or as often as needed.