Louisville Tin and Stove W506F, W505F Rough-Ininstructions Figure, Rough-In Dimensions, Page

Models: W506F W505F W255F W256F

1 25
Download 25 pages 48.25 Kb
Page 8
Image 8
ROUGH-IN INSTRUCTIONS

ROUGH-IN INSTRUCTIONS

FIGURE 1

ROUGH-IN

DIMENSIONS

 

*65-3/4”

14-1/4”

* This

Min.

measurement

14-1/2” Max.

must be

 

taken from

top of floor plate

4”

4”

NOTE: For proper combustion, make sure units are level, front to back and side to side.

Dry-Wall

B-W Type Vent

Screw

Front

Panel

Plaster

Ground

NOTE: Front Panel must be in front of plaster ground channel. Do not hang it over front of plaster ground.

FIGURE 5A- DRYWALL

Plaster

B-W Type Vent

Screw

Front

Panel

Plaster

Ground

NOTE: Front Panel must be in front of plaster ground channel. Do not hang it over front of plaster ground.

FIGURE 5B - PLASTER WALL

STEP 4.Remove double ceiling plate between studs. Install one ceiling plate spacer across the cut out in ceiling plate. Install vent pipe into position, be sure to lock bottom of vent pipe into the base plate. Nail second ceiling plate spacer in place. (See Figure C, Page 6).

STEP 5.If the vent continues through additional stories within the 2x4-stud space, then fire-stop-spacers must be installed at the second and subsequent ceiling levels. See Figure D.

 

Installation of B-W gas

Firestop spacers

 

supplied by

 

vent for each subsequent

 

manufacturer of

 

ceiling or floor level

 

B-W gas vent

 

of multi-story

 

 

 

buildings

 

Plate cut away to

 

 

 

provide passage of

 

 

 

B-W gas vent

 

 

 

Nail firestop

 

 

 

spacer securely

 

 

 

 

FIGURE D

 

 

 

 

 

 

VENT INSTALLATION

LISTED

 

 

2 FT. MIN.

VENT TOP

 

 

 

 

 

 

STORM COLLAR

 

 

 

ROOF

 

 

 

FLASHING

 

CEILING PLATE

OVAL TO

 

ROUND ADAPTER

 

SPACERS

 

 

 

 

 

LISTED “BW”

 

 

 

VENT PIPE

 

12 FT.

CEILING

BASE PLATE

 

MIN.

 

 

 

PLATE

 

 

 

HEADER PLATE

 

 

SPACER

 

 

LANCES

 

 

 

 

2 X 4 WALL

 

 

 

STUDS

 

 

 

 

FIGURE 2 - VENT INSTALLATION

Page 8

Page 8
Image 8
Louisville Tin and Stove W506F, W505F, W256F, W255F warranty Rough-Ininstructions Figure, Rough-In Dimensions, Page