Lowrance electronic X67C manual Speed/Temperature Sensors, Spread epoxy here Sand this surface

Models: X67C

1 80
Download 80 pages 14.42 Kb
Page 19
Image 19

Spread epoxy here

Sand this surface

Epoxy transducer to hull.

Place the transducer into the epoxy, twisting and turning it to force any air bubbles out from under the transducer face. The face of the transducer should be parallel with the hull, with a minimum amount of epoxy between the hull and transducer. After the epoxy dries, re- member to fill in the area around the transducer with more epoxy and route the cable to the sonar unit.

Speed/Temperature Sensors

The X67C can accept as many as two temperature sensors, which can be used to monitor the temperature of surface water, a live well or some other location. These units can accept an optional speed sensor for show- ing speed and distance traveled. However, you can only use one accessory at a time. If you would like to use a speed sensor and a secondary tem- perature sensor at the same time, you will need a combination device.

NOTE:

If a second temp sensor is used, it must be the model TS-2U. This model has a fixed electronic "address" which designates it as the second of two temp sensors.