Manuals
/
Brands
/
Computer Equipment
/
Network Card
/
LSI
/
Computer Equipment
/
Network Card
LSI
Series 520 manual
122
1
122
124
124
Download
124 pages, 1.29 Mb
IX-4
Index
Copyright © 2002 by LSI Logic Corporation. All rights reserved.
Contents
HARDWARE
GUIDE
Page
FCC Regulatory Statement
Warning:
Disclaimer –
Page
Preface
Page
MegaRAID Problem Report Form (Cont.)
Logical Drive Configuration
Logical Drive Configuration (Cont.)
Physical Device Layout
Physical Device Layout (Cont.)
Page
Page
Contents
Page
Configuring Physical Drives, Arrays, and Logical Drives
Appendix A
SCSI Cables and Connectors
Appendix B
Appendix C
Index
Customer Feedback
Page
Overview
1.1Features
1.2SCSI Channel
1.3NVRAM and Flash ROM
1.4SCSI Connectors
1.5Single-Endedand Differential SCSI Buses
1.6Maximum Cable Length for SCSI Standards
1.7SCSI Bus Widths and Maximum Throughput
1.8Documentation
1.8.1MegaRAID SCSI 320-1Hardware Guide
1.8.2MegaRAID Configuration Software Guide
1.8.3MegaRAID Operating System Driver Installation Guide
Page
Introduction to RAID
2.1RAID Benefits
2.1.1Improved I/O
2.1.2Increased Reliability
2.2MegaRAID SCSI 320-1– Host-BasedRAID Solution
2.2.1Host-BasedRAID
2.2.2SCSI-to-SCSIExternal RAID
2.3RAID Overview
2.3.1Physical Array
2.3.2Logical Drive
2.3.3Consistency Check
2.3.4Fault Tolerance
2.3.5Disk Striping
Figure 2.1 Disk Striping
2.3.5.1Stripe Width
2.3.6Disk Mirroring
2.3.7Disk Spanning
2.3.8Parity
2.3.9Hot Spares
2.3.10 Hot Swapping
2.3.11 Disk Rebuild
2.3.12 Logical Drive States
2.3.13 SCSI Drive States
2.3.14 Disk Array Types
2.3.15 Enclosure Management
Page
RAID Levels
3.1Selecting a RAID Level
3.2RAID
3.3RAID
3.4RAID
Figure 3.3 RAID 5 Array
3.5RAID
3.6RAID
Figure 3.5 RAID 50 Array
Features
4.1SMART Technology
4.2Configuration on Disk
4.3Configuration Features
4.4Array Performance Features
4.5RAID Management Features
4.6Fault Tolerance Features
4.7Software Utilities
4.8Operating System Software Drivers
4.9MegaRAID SCSI 320-1Specifications
4.9.1PCI Bridge/CPU
4.9.2Cache Memory
4.9.3MegaRAID BIOS
4.9.4Serial Port
4.9.5SCSI Bus
4.9.6SCSI Connectors
4.9.7SCSI Termination
4.9.8SCSI Firmware
4.10 RAID Management
4.10.1MegaRAID BIOS Configuration Utility
4.10.2 WebBIOS Configuration Utility
4.10.3 Power Console Plus
4.10.4 MegaRAID Manager
4.11 Compatibility
4.11.1Server Management
4.11.2 SCSI Device Compatibility
4.11.3 Software
Page
Configuring Physical Drives
Arrays, and Logical Drives
5.1Configuring SCSI Physical Drives
5.1.1Basic Configuration Rules
5.1.2Current Physical Device Configuration
5.1.3Logical Drive Configuration
Page
5.1.4Physical Device Layout
Table 5.3 Physical Device Layout (Cont.)
Page
5.2Configuring Arrays
5.2.1Arranging Arrays
5.2.2Creating Hot Spares
5.3Creating Logical Drives
5.3.1Configuration Strategies
Capacity for RAID Levels (Cont.)
5.3.1.2Maximizing Drive Availability
Fault Tolerance for RAID Levels
5.3.1.3Maximizing Drive Performance
5.3.2Assigning RAID Levels
5.4Configuring Logical Drives
5.4.1Optimizing Data Storage
5.5Planning the Array Configuration
5.5.1Using the Array Configuration Planner
Table 5.9 Array Configuration Planner
Array Configuration Planner (Cont.)
Page
Hardware Installation
6.1Hardware Requirements
6.2Installation Steps
6.2.1Step 1: Unpack
6.2.2Step 2: Power Down
6.2.3Step 3: Check Jumper Settings
Figure 6.1 MegaRAID SCSI 320-1Controller Layout
6.2.3.1J2 Dirty Cache LED
6.2.3.2J3 Clear EPROM
6.2.3.3J4 BIOS Enable
Table 6.3 Pinout for J4 BIOS Enable
6.2.3.4J5 SCSI Activity LED
6.2.3.5J6 Serial Port
6.2.4Step 4: Set Termination
6.2.4.2Selecting a Terminator
6.2.4.3Terminating Internal SCSI Disk Arrays
Figure 6.2 Termination of Internal SCSI Disk Arrays
6.2.4.4Terminating External Disk Arrays
Figure 6.3 Terminating External Disk Arrays
6.2.4.5Terminating Internal and External Disk Arrays
Figure 6.4 Terminating Internal and External Disk Arrays
6.2.4.6Connecting Non-DiskSCSI Devices
Caution:
Figure 6.5 Connecting Non-DiskSCSI Devices
6.2.5Step 5: Install MegaRAID SCSI
6.2.6Step 6: Connect SCSI Devices
6.2.7Step 7: Set Target IDs
Important:
6.2.7.1Example of MegaRAID SCSI 320-1ID Mapping
Example of Mapping for SCSI
6.2.8Step 8: Power Up
6.2.9Step 9: Run the MegaRAID BIOS Configuration Utility
6.2.10 Step 10: Install the Operating System Driver
6.3Summary
Troubleshooting
7.1General Troubleshooting
General Problems and Suggested Solutions (Cont.)
7.2BIOS Boot Error Messages
7.3Other BIOS Error Messages
7.4Other Potential Problems
Other Potential Problems (Cont.)
Appendix A
SCSI Cables and
Connectors
A.1 68-Pin High-DensitySCSI Internal Connector
A.1.1 Cable Assembly for Internal Wide SCSI Devices
A.1.2 Connecting Internal and External Wide Devices
A.1.3 Converting Internal Wide to Internal Non-Wide(Type 2)
A.1.4 Converting Internal Wide to Internal Non-Wide(Type 30)
A.1.5 Converting from Internal Wide to Internal Non-Wide(Type 3)
A.2 SCSI Cable and Connector Vendors
A.3 High-Density 68-PinConnector Pinout for SE SCSI
Page
A.4 68-PinConnector Pinout for LVD SCSI
Table A.4 68-PinConnector Pinout for LVD SCSI (Cont.)
Appendix B
Audible Warnings
Page
Appendix C Glossary
Channel
Consistency
Check
Cold Swap
Data Transfer
Disk Subsystem
Double Buffering
Failed Drive
Fast SCSI
Firmware
Host Computer
Hot Spare
Hot Swapping
I/O Driver
Initialization
Mbyte
Multi-threaded
Operating Environment
Parity
Partition
RAID
RAID Migration
Read-Ahead
Ready State
Rebuild
Redundancy
Replacement
Unit
SAF-TE
SCSI
Service Provider
SNMP
Spanning
Spare
Striping
Ultra320
Virtual Sizing
Wide SCSI
Page
Index
Page
Page
Page
Customer Feedback
Reader’s Comments